Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Accuracy of Low-Dose and Ultra-Low-Dose Computed Tomography for Nephrolithiasis in Obesity: A Multicenter Review

Gabriel E. Martin; Kymora Scotland; Jason Smith; Ninous Betdashtoo; Mohammad Kassir; Ellie Mehrara; Ruben Crew; Zhamshid Okhunov; D. Duane Baldwin (2026). Urology

DOI 10.1016/j.urology.2026.09.036

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Objective To evaluate the diagnostic accuracy of low-dose (LD) and ultra-low-dose (ULD) computed tomography (CT) scan for stone identification in obese patients compared to conventional-dose CT. Methods A review of patients undergoing CT scans for kidney or ureteral stones at two academic institutions was conducted. Patients with body mass index (BMI) >30 kg/m 2 and both a conventional and LD CT within 100 days of each other were included. LD was defined as <4 millisieverts (mSv) and ULD as <1.9 mSv. Renal units with interval treatment or documented stone passage were excluded. CTs were reviewed by board-certified radiologists. Results Fifty-two patients met inclusion criteria with mean BMI of 36.2 kg/m 2 (range: 30.2-63.8). The combined average effective dose of LD and ULD CT was significantly lower than conventional CT (2.3 vs 14.9 mSv; p<0.001), an 85% reduction. LD and ULD CT detected 92/96 stones >2 mm (96% sensitivity) and 95/115 stones overall (83% sensitivity). All stones missed were ≤4 mm in size. LD CT BMI-stratified analysis demonstrated 100% sensitivity for stones >2 mm for BMI 30-35 and >40 kg/m 2 , and 90% for BMI 35-40 kg/m 2 . ULD CT demonstrated 100% sensitivity for stones >2 mm for BMI 30-35 kg/m 2 . Conclusion Overall, LD and ULD CT in obese patients accurately identified stones >2 mm with 96% sensitivity, while reducing radiation dose by 85%. This multicenter study supports the accuracy of LD CT for stone identification in noninfected obese patients across BMI subgroups, with ULD CT best reserved for patients with BMI 30-35 kg/m 2 .

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=5; title_english_share=0.2941; title_reads=english; abstract_words=234; abstract_english_function_words=66; abstract_english_share=0.2821; abstract_reads=english; language_check=metadata_listed