Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Early Lung Cancer Diagnosis from Virtual Follow-up LDCT Generation via Correlational Autoencoder and Latent Flow Matching
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Lung cancer is one of the most commonly diagnosed cancers, and early diagnosis is critical because the survival rate declines sharply once the disease progresses to advanced stages. However, achieving an early diagnosis remains challenging, particularly in distinguishing subtle early signals of malignancy from those of benign conditions. In clinical practice, a patient with a high risk may need to undergo an initial baseline and several annual follow-up examinations (e.g., CT scans) before receiving a definitive diagnosis, which can result in missing the optimal treatment. Recently, Artificial Intelligence (AI) methods have been increasingly used for early diagnosis of lung cancer, but most existing algorithms focus on radiomic features extraction from single early-stage CT scans. Inspired by recent advances in diffusion models for image generation, this paper proposes a generative method, named CorrFlowNet, which creates a virtual, one-year follow-up CT scan after the initial baseline scan. This virtual follow-up would allow for an early detection of malignant/benign nodules, reducing the need to wait for clinical follow-ups. During training, our approach employs a correlational autoencoder to encode both early baseline and follow-up CT images into a latent space that captures the dynamics of nodule progression as well as the correlations between them, followed by a flow matching algorithm on the latent space with a neural ordinary differential equation. An auxiliary classifier is used to further enhance the diagnostic accuracy. Evaluations on a real clinical dataset show our method can significantly improve downstream lung nodule risk assessment compared with existing baseline models. Moreover, its diagnostic accuracy is comparable with real clinical CT follow-ups, highlighting its potential to improve cancer diagnosis.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=277; abstract_english_function_words=93; abstract_english_share=0.3357; abstract_reads=english; language_check=metadata_listed