Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Time-frequency domain prior constrained deep unfolding network for low-dose CT reconstruction

Xiong Zhang; Xinbo Zhang; Xinzhong Li; Zulfiqur Ali; Yue Wang; Hong Shangguan; Xueying Cui (2025). Journal of X-Ray Science and Technology

DOI 10.1177/08953996251319187

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low-dose computed tomography (LDCT) effectively reduces the risk of malignant disease; however, reducing the radiation dose introduces additional noise and stripe artifacts in the CT imaging process. While Convolutional Neural Networks (CNN) have demonstrated performance advantages in LDCT imaging tasks, their end-to-end network architecture limits adaptability to CT reconstruction tasks, leaving room for further performance improvement. OBJECTIVE: To propose a low-dose CT reconstruction network based on the iterative algorithms, incorporating an interpretable network architecture to achieve superior reconstruction performance. METHODS: To better adapt to CT reconstruction tasks, we proposed an interpretable deep unfolding network leveraging time-frequency and image domain priors to fully exploit the features extracted in the transform domain. The iterative optimization process of the proposed algorithm is mapped into a deep unfolding network, and a Stage Information Memory Network (SIMN) is designed to address information loss between adjacent stages and within each stage. RESULTS: Experimental results on Mayo and Piglet datasets show that the proposed model outperforms state-of-the-art techniques in both quantitative metrics and visual quality. CONCLUSIONS: The proposed network effectively removes artifacts and noise from low-dose CT images, achieving excellent reconstruction performance.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=1; title_english_share=0.0769; title_reads=not_english; abstract_words=195; abstract_english_function_words=54; abstract_english_share=0.2769; abstract_reads=english; language_check=metadata_listed