Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose non-contrast examination of the temporal bone using volumetric 320-row computed tomography

Berhan Pirimoglu; Recep Sade; Muhammed Sedat Sakat; Gokhan Polat; Mecit Kantarci (2018). Acta Radiologica

DOI 10.1177/0284185118802597

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Background320-row volume computed tomography (CT) allows CT dose to be reduced while maintaining image quality. PurposeTo evaluate image quality of low-dose non-contrast temporal bone CT using single volumetric 320-row multidetector CT technique. Material and MethodsA total of 125 patients were included in our study. Two low-dose protocols, including 135 kV tube voltage with 5 mAs tube current and 80 kV tube voltage with 5 mAs tube current, were chosen based on results of present phantom study. For evaluating subjective image quality, conspicuity of anatomic landmarks were assigned a score using a five-point scale. Objective image quality analysis was performed by analyzing regions of interest on axial soft-tissue and bone reconstructions. Effective dose was calculated from dose-length product. ResultsMean effective radiation dose for 120 kV and 75 mAs protocol (control group) was 0.29 ± 0.04 mSv; for 135 kV and 5 mAs protocol (study group A), this value was 0.02 ± 0. 003 mSv; and for 80 kV and 5 mAs protocol (study group B), this value was 0.005 ± 0. 0009 mSv. Mean effective radiation doses of study group A and B were significantly lower than the control group (P < 0.001). Study group A and control group images showed no significant difference in image quality except for some anatomic landmarks. Study group B images had lower image quality than control group images. ConclusionsTemporal bone CT with 135 kVp and 5 mAs can be performed at very low radiation exposure while maintaining high image quality.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=226; abstract_english_function_words=60; abstract_english_share=0.2655; abstract_reads=english; language_check=metadata_listed