Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Radiation exposure associated with computed tomography for pediatric urolithiasis evaluation: A scoping review of the literature
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
INTRODUCTION: Computed tomography (CT) imaging is used for assessment of pediatric urolithiasis in cases where ultrasound is inconclusive. The utility of CT imaging must be considered alongside the potential risks of radiation exposure in this patient population due to the increased risk of cancer development. The purpose of this review is to investigate the radiation exposure associated with standard-dose and low-dose computed tomography (CT) imaging for the assessment of pediatric urolithiasis. METHODS: A scoping literature review over a 23 year period between 2000 and 2023 was conducted of all English-language studies reporting on the use of non-contrast CT imaging for assessment of pediatric urolithiasis. Patients that were specified as pediatric with age ≤20 years at time of intervention and undergoing standard-dose or low/ultra-low-dose CT were included. Low-dose and ultra-low-dose CT were defined as a radiation dose ≤3.0 mSv and ≤1.9 mSv, respectively. RESULTS: A total of 8121 articles were identified and after screening, 6 articles representing 309 patients were included in this scoping review. Of the articles reviewed, standard non-contrast CT radiation doses for pediatric urolithiasis evaluation ranged from 2.9 to 5.5 mSv and low-dose CT radiation dose was reported to be 1.0-2.72 mSv. Only 2 studies directly evaluated low-dose CT imaging compared to standard-dose CT imaging for pediatric urolithiasis assessment. Radiation reduction approaches did not negatively impact urolithiasis detection or characterization in 2 studies reviewed. CONCLUSIONS: CT radiation doses for suspected or known pediatric urolithiasis are underreported and vary greatly with underutilization of low-dose/ultra-dose protocols for pediatric urolithiasis especially in comparison to the adult population. Results from this scoping review support that low-dose CTprotocols for pediatric stone disease are feasible to reduce radiation exposure.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=16; title_english_function_words=5; title_english_share=0.3125; title_reads=english; abstract_words=280; abstract_english_function_words=95; abstract_english_share=0.3393; abstract_reads=english; language_check=metadata_listed