Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Influence of tube potential on quantitative coronary plaque analyses by low radiation dose computed tomography: a phantom study
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Previous studies have shown that employing the low dose computed tomography (CT) technique based on low tube potential reduces the radiation dose required for the coronary artery examination protocol. However, low tube potential may adversely influence the CT number of plaque composition. Therefore, we aimed to determine whether quantitative atherosclerotic plaque analysis by a multi-slice, low radiation dose CT protocol using 80 kilovolts (kV) yields results comparable to those of the standard 120 kV protocol. Artificial plaque samples (n = 17) composed of three kinds of plaque were scanned at 120 and 80 kV. Relative low-density and medium-density plaque component volumes obtained by three protocols (80 kV, 60 Hounsfield units [HU] threshold; 120 kV, 60 HU threshold; and 80 kV, 82 HU threshold) were compared. Using the 60 HU threshold, relative volume of the low-density plaque component obtained at 80 kV was lower than that obtained at 120 kV (27 ± 3% vs. 51 ± 5%, P < 0.001), whereas relative volume of the medium-density plaque component obtained at 80 kV was higher than that obtained at 120 kV (73 ± 3% vs. 48 ± 5%, P < 0.001). By contrast, no significant difference in relative volume obtained at 80 kV (82 HU threshold) versus 120 kV (60 HU threshold) was observed for either low-density (52 ± 5% vs. 51 ± 5%) or medium-density (48 ± 5% vs. 48 ± 5%) plaque component. Low tube potential may affect the accuracy of quantitative atherosclerotic plaque analysis. For our phantom test, 82 HU was the optimal threshold for scanning at 80 kV.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=216; abstract_english_function_words=61; abstract_english_share=0.2824; abstract_reads=english; language_check=metadata_listed