Does Iterative Reconstruction Improve Image Quality and Reduce Dose in Computed Tomography?

Dejian Qiu; Euclid Seeram (2016). Radiology - Open Journal

DOI 10.17140/roj-1-108

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

The Filtered Back Projection (FBP) algorithm has been the standard algorithm for image reconstructionin computed tomography (CT) for many years, but it creates possible streak artifactsand a notable increase in image noise when radiation dose is reduced exceedingly. Withtechnological advancement and increased computational capacities in workstations, iterativereconstruction (IR) algorithms have re-emerged as a potential alternative. The purpose of thisreview is to establish if there is a general consensus that IR algorithms faithfully reduce radiationdose and improve image quality in CT in comparison with the FBP algorithm. A systematicreview of the literature from 2012 to 2015 was conducted using Ovid MEDLINE and PubMeddatabases, as well as various well-known journals such as the American Journal of Roentgenology,European Journal of Radiology, Physica Medica and the Korean Journal of Radiology.A total of 57 articles were categorized as either synopsis articles or performance evaluationclinical studies, where the latter was further divided into 6 sub-categories according to the typeof IR algorithm examined. The results show that the use of IR algorithms reduces objectiveimage noise, and at least preserves spatial resolution and low contrast detectability, even whendose is reduced. The findings are also applicable to specific patient groups, such as pediatricsand obese patients. In conclusion, there is a general consensus that IR algorithms can faithfullyreduce radiation dose and improve image quality in CT in comparison with the FBP algorithm.

From Crossref.