Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
OBJECTIVE: To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. METHODS: A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. RESULTS: According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm(3)). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CONCLUSIONS: CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. KEY POINTS: • Computer-aided detection (CAD) has known advantages for computed tomography (CT). • Combined CAD/nodule size cut-off parameters assist CT lung cancer screening. • This combination improves the sensitivity of pulmonary nodule detection by CT. • It increases the positive predictive value for cancer detection.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=19; title_english_function_words=5; title_english_share=0.2632; title_reads=english; abstract_words=251; abstract_english_function_words=84; abstract_english_share=0.3347; abstract_reads=english; language_check=metadata_listed