Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Hip Imaging in Children With Cerebral Palsy: Estimation and Intrapatient Comparison of Patient-Specific Radiation Doses of Low-Dose CT and Radiography

Reyhaneh Nosrati; Da Zhang; Michael J. Callahan; Benjamin J. Shore; Andy Tsai (2022). Investigative Radiology

DOI 10.1097/rli.0000000000000920

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: Hip displacement is the second most common orthopedic problem affecting children with cerebral palsy (CP). Routine radiographic hip surveillance typically involves an anteroposterior (AP) pelvis radiograph. Unfortunately, this imaging protocol is limited by its projectional technique and the positioning challenges in children with CP. Alternatively, hip low-dose computed tomography (LDCT) has been advocated as a more accurate strategy for imaging surveillance as it provides biofidelic details of the hip that is independent of patient positioning. However, the tradeoff is the (presumed) higher radiation dose to the patient. The goal of this study is to estimate patient-specific radiation doses of hip LDCTs and AP pelvis radiographs in CP patients, and perform an intrapatient dose comparison. MATERIALS AND METHODS: A search of our imaging database was performed to identify children with CP who underwent hip LDCT and AP pelvis radiograph within 6 months of each other. The LDCTs were performed using weight-adjusted kVp and tube current modulation, whereas the radiographs were obtained with age-/size-adjusted kVp/mAs. The patient-specific organ and effective doses for LDCT were estimated by matching the patients to a nonreference pediatric phantom library from the National Cancer Institute Dosimetry System for Computed Tomography database with Monte Carlo-based dosimetry. The patient-specific organ and effective doses for radiograph were estimated using the National Cancer Institute Dosimetry System for Radiography and Fluoroscopy with Monte Carlo-based dose calculation. Dose conversion k-factors of dose area product for radiography and dose length product for LDCT were adapted, and the estimation results were compared with patient-specific dosimetry. RESULTS: Our study cohort consisted of 70 paired imaging studies from 67 children (age, 9.1 ± 3.3 years). The patient-specific and dose length product-based effective doses for LDCT were 0.42 ± 0.21 mSv and 0.59 ± 0.28 mSv, respectively. The patient-specific and dose area product-based effective doses for radiography were 0.14 ± 0.09 mSv and 0.08 ± 0.06 mSv, respectively. CONCLUSIONS: The radiation dose for a hip LDCT is ~4 times higher than pelvis radiograph, but it is still very low and poses minimal risk to the patient.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=22; title_english_function_words=6; title_english_share=0.2727; title_reads=english; abstract_words=336; abstract_english_function_words=116; abstract_english_share=0.3452; abstract_reads=english; language_check=metadata_listed