Diagnostic Accuracy of Computed Tomography Pulmonary Angiography With Reduced Radiation and Contrast Material Dose: A Prospective Randomized Clinical Trial
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
OBJECTIVE: The objective of the study was to test the diagnostic performance of low-dose computed tomography pulmonary angiography (CTPA) at peak tube voltage of 80 kVp with both reduced radiation and reduced contrast material (CM) dose. MATERIALS AND METHODS: In this single-center, single-blinded prospective randomized trial, 501 patients with body weights of less than 100 kg with suspected acute pulmonary embolism (PE) were assigned to normal-dose CTPA (100-kVp tube energy and 100-mL CM, 255 patients) and low-dose CTPA (80-kVp tube energy and 75-mL CM, 246 patients). Primary end points were evidence of PE in CTPA and accuracy of CTPA on a composite reference standard. Results were compared by calculating the odds ratio with the 95% confidence interval. RESULTS: The reference diagnosis was equivocal in 20 of the 501 patients. Diagnosis of CTPA was correct in 240 patients and incorrect in 5 in the normal-dose group. Computed tomography pulmonary angiography was correct in 230 patients and incorrect in 6 in the low-dose group (odds ratio, 1.25; 95% confidence interval, 0.38-4.16; P = 0.77). Sensitivity was 96.9% and 100% and specificity was 98.1% and 97.1% in the normal-dose and low-dose groups, respectively. No PE or PE-related death occurred during the 90-day follow-up. The size-specific dose estimates were 30% lower at 80 kVp (4.8 ± 1.0 mGy) compared with that at 100 kVp (6.8 ± 1.2 mGy; P < 0.001). CONCLUSIONS: The accuracy of low-dose CTPA at 80 kVp with a 30% reduced radiation dose and a 25% lower CM volume is not significantly different from that of normal-dose CTPA at 100 kVp in detecting acute PE in patients weighing less than 100 kg.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=19; title_english_function_words=4; title_english_share=0.2105; title_reads=english; abstract_words=248; abstract_english_function_words=87; abstract_english_share=0.3508; abstract_reads=english; language_check=metadata_listed