Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Unenhanced Multi-Detector Low-Dose vs Standard-Dose Computed Tomography in Patients Having Urinary Tract Calculi. A Practical Approach in Optimizing Patient's Dose, Experience at Jinnah Postgraduate Medical Center, Karachi

Marya Hameed; Ameet Jesrani; Sehrish Mehreen; Naveed Ahmed; Tariq Mahmood (2018). Journal of the Dow University of Health Sciences

DOI 10.36570/jduhs.2018.2.552

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Objective: This study is designed to assess the diagnostic accuracy of Low-dose unenhanced multi detector computed tomography (MDCT) in patients with suspected urinary tract calculi taking Standard-dose unenhanced MDCT as gold standard. Methods: The cross-sectional study was conducted from July to December 2016 among patients with suspected urinary tract calculi. The patients underwent unenhanced low-dose MDCT scan with reconstruction slice thickness, 7.0 mm; pitch= 1.00; tube potential 120kV; and tube charge per gantry rotation, 25-50 m As, followed by standard-dose computed tomography (CT) scan. Diagnostic accuracy of unenhanced low dose multi-detector computed tomography was calculated taking standard dose MDCT as gold standard. Results: Out of total 50 adult patients, 32 (64%) were males and 18 (36%) were females. The mean age of the patients was 50 ± 11 years. The diagnostic accuracy of Low dose CT showed 100% sensitivity when compared with Unenhanced Standard dose CT in diagnosing urinary tract calculi, indirect signs of obstruction and adjacent organs. However, a difference was observed in blood vessels within the renal sinus which were seen in 48 kidneys in low dose CT and 49 in standard dose CT (True positive 96%, true negative 100%). Conclusion: Low dose MDCT can be effectively used for the evaluation of urinary tract calculi with significantly decrease radiation dose to the patients compared with standard dose CT. This is due to the improvements in CT technology which allow isotropic resolution with faster scan coverage in a single, short breath-hold, and high diagnostic performance.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=31; title_english_function_words=4; title_english_share=0.1290; title_reads=english; abstract_words=236; abstract_english_function_words=68; abstract_english_share=0.2881; abstract_reads=english; language_check=metadata_missing