Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Outstanding negative prediction performance of solid pulmonary nodule volume AI for ultra-LDCT baseline lung cancer screening risk stratification

Harriet L. Lancaster; Sunyi Zheng; Olga O. Aleshina; Donghoon Yu; Valeria Yu. Chernina; Marjolein A. Heuvelmans; Geertruida H. de Bock; Monique D. Dorrius; Jan Willem Gratama; Sergey P. Morozov; Victor A. Gombolevskiy; Mario Silva; Jaeyoun Yi; Matthijs Oudkerk (2022). Lung Cancer

DOI 10.1016/j.lungcan.2022.01.002

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Objective To evaluate performance of AI as a standalone reader in ultra-low-dose CT lung cancer baseline screening, and compare it to that of experienced radiologists. Methods 283 participants who underwent a baseline ultra-LDCT scan in Moscow Lung Cancer Screening, between February 2017–2018, and had at least one solid lung nodule, were included. Volumetric nodule measurements were performed by five experienced blinded radiologists, and independently assessed using an AI lung cancer screening prototype (AVIEW LCS, v1.0.34, Coreline Soft, Co. ltd, Seoul, Korea) to automatically detect, measure, and classify solid nodules. Discrepancies were stratified into two groups: positive-misclassification (PM); nodule classified by the reader as a NELSON-plus /EUPS-indeterminate/positive nodule, which at the reference consensus read was < 100 mm 3 , and negative-misclassification (NM); nodule classified as a NELSON-plus /EUPS-negative nodule, which at consensus read was ≥ 100 mm 3 . Results 1149 nodules with a solid-component were detected, of which 878 were classified as solid nodules. For the largest solid nodule per participant (n = 283); 61 [21.6 %; 53 PM, 8 NM] discrepancies were reported for AI as a standalone reader, compared to 43 [15.1 %; 22 PM, 21 NM], 36 [12.7 %; 25 PM, 11 NM], 29 [10.2 %; 25 PM, 4 NM], 28 [9.9 %; 6 PM, 22 NM], and 50 [17.7 %; 15 PM, 35 NM] discrepancies for readers 1, 2, 3, 4, and 5 respectively. Conclusion Our results suggest that through the use of AI as an impartial reader in baseline lung cancer screening, negative-misclassification results could exceed that of four out of five experienced radiologists, and radiologists' workload could be drastically diminished by up to 86.7%.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=2; title_english_share=0.1053; title_reads=english; abstract_words=233; abstract_english_function_words=74; abstract_english_share=0.3176; abstract_reads=english; language_check=metadata_listed