Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Radiomics in the evaluation of lung nodules: Intrapatient concordance between full-dose and ultra-low-dose chest computed tomography

Pierre-Alexis Autrusseau; Aïssam Labani; Pierre De Marini; Pierre Leyendecker; Cédric Hintzpeter; Anne-Claire Ortlieb; Michael Calhoun; Ilya Goldberg; Catherine Roy; Mickael Ohana (2021). Diagnostic and Interventional Imaging

DOI 10.1016/j.diii.2021.01.010

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

PURPOSE: The purpose of this study was to retrospectively evaluate the quantitative and qualitative intrapatient concordance of pulmonary nodule risk assessment by commercially available radiomics software between full-dose (FD) chest-CT and ultra-low-dose (ULD) chest CT. MATERIALS AND METHODS: Between July 2013 and September 2015, 68 patients (52 men and16 women; mean age, 65.5±10.6 [SD] years; range: 35-87 years) with lung nodules≥5mm and<30mm who underwent the same day FD chest CT (helical acquisition; 120kV; automated tube current modulation) and ULD chest CT (helical acquisition; 135kV; 10mA fixed) were retrospectively included. Each nodule on each acquisition was assessed by a commercial radiomics software providing a similarity malignancy index (mSI), classifying it as "benign-like" (mSI<0.1); "malignant-like" (mSI>0.9) or "undetermined" (0.1≤mSI≤0.9). Intrapatient qualitative agreement was evaluated with weighted Cohen-Kappa test and quantitative agreement with intraclass correlation coefficient (ICC). RESULTS: Ninety-nine lung nodules with a mean size of 9.14±4.3 (SD) mm (range: 5-25mm) in 68 patients (mean 1.46 nodule per patient; range: 1-5) were assessed; mean mSI was 0.429±0.331 (SD) (range: 0.001-1) with FD chest CT (22/99 [22%] "benign-like", 67/99 [68%] "undetermined" and 10/99 [10%] "malignant-like") and mean mSI was 0.487±0.344 (SD) (range: 0.002-1) with ULD chest CT (20/99 [20%] "benign-like", 59/99 [60%] "undetermined" and 20/99 [20%] "malignant-like"). Qualitative and quantitative agreement of FD chest CT with ULD chest CT were "good" with Kappa value of 0.60 (95% CI: 0.46-0.74) and ICC of 0.82 (95% CI: 0.73-0.87), respectively. CONCLUSION: A good agreement in malignancy similarity index can be obtained between ULD chest CT and FD chest CT using radiomics software. However, further studies must be done with more case material to confirm our results and elucidate the diagnostic capabilities of radiomics software using ULD chest CT for lung nodule characterization by comparison with FD chest CT.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=5; title_english_share=0.2632; title_reads=english; abstract_words=273; abstract_english_function_words=74; abstract_english_share=0.2711; abstract_reads=english; language_check=metadata_listed