Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Detection of Lung Regions from LDCT Images and 3D Image Registration Using FFD

Chika Tanaka; Tohru Kamiya; Takashi Terasawa; Takatoshi Aoki (2025). 2025 9th International Conference on Biomedical Engineering and Applications (ICBEA)

DOI 10.1109/icbea66055.2025.00013

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

In recent years, lung cancer is a serious disease worldwide. To overcome the disease, early detection and early treatment of lung cancer are important tasks. In Japan, CT (Computed Tomography) examination is performed in many medical facilities for visual screening. However, there is a problem that huge number of images taken by CT is a burden to the doctor. Therefore, the CAD (Computer Aided Diagnosis) system is in the spotlight to reduce the burden. On the other hand, in CT screening, LDCT (Low Dose Computed Tomography) is desirable considering radiation exposure. However, the LDCT image is characterized by lower image quality at lower dose. Therefore, a CAD that can be applied to LDCT is needed. In this paper, we propose a lung field detection method and a three-dimensional (3D) registration method to generate temporal subtraction images that can be applied to LDCT images. Our method consists of the following steps: detection of lung regions using an active contour model, correction of corresponding slices between images, global matching based on the center of gravity, setting the VOI (volume of interest), and local matching on the VOI. In this paper, we apply our method to LDCT images of 7 cases. In addition, we conducted a comparison experiment with other registration methods. In the proposed method, a decrease of 7.55% in FWHM and 34.4% in sum of histogram of temporal subtraction images compared to the other method, and its usefulness was verified.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=237; abstract_english_function_words=97; abstract_english_share=0.4093; abstract_reads=english; language_check=metadata_missing