Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Quantitative Assessment of Airways with Deep Learning and Low Dose CT Imaging
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Rationale: Riding on recent advances in imaging technologies and analytic methods, low dose computed tomography (CT) has emerged as a viable alternative for longitudinal lung studies, where cumulative radiation exposure is a serious concern. CT-based airway metrics play important roles in understanding the etiology behind chronic obstructive pulmonary disease (COPD) severity, progression, and outcomes. Here, we evaluate the performance of a state-of-the-art low dose CT-based method for assessment of airway metrics. Methods: We used standard and low dose CT scans (CTDI vol of 13.3 and 2.2 mGy, respectively) at total lung capacity (TLC) acquired at first follow-up visits of the Iowa cohort of the COPDGene study. A deep learning (DL)-based freeze-and-grow method was applied to segment the airway tree from CT scans, which was processed through an automated pipeline. Total airway count (TAC), sub-sub-segmental (up to generation 6) TAC (TAC s ), peripheral (generation 7 and beyond) TAC (TAC p ), and generational airway count along with airway lumen cross-sectional area (CSA) and wall thickness were computed. Airway lumen CSA and wall thickness were normalized by subject-specific maximum lung CSA and its square root, respectively. Descriptive statistics of means and standard deviations (SDs) and student's t-tests were used for data analysis. Results: Matching standard and low dose CT scans of 235 subjects (age 69.79.0 (meanSD) years; 119 females; COPD GOLD stage (n) 0: 108; 1: 55; 2: 54; 3: 15; 4: 3) were studied with 15, 162, and 58 never, current, and exsmokers, respectively. Different airway counts at standard and low dose CT scans were 371.811.5 and 269.29.0 for TAC, 119.55.5 and 112.56.5 for TAC s , and 252.317.0 and 156.315.5 for TAC p , respectively, and the differences were significant (p < 0.05) for TAC and TAC p . Beyond the 6 th generation, i.e., the sub-sub-segmental level, airway counts at standard radiation dose were significantly higher than low dose-derived counts (Figure The difference in airway CSA was significant between 7 to 9 generations, while the difference in wall thickness was significant between 7 to 11 generations. No significant differences were observed in airway CSA and wall thickness at matching locations up to the sub-sub-segmental level. Conclusion: Emerging technologies of low dose CT imaging and state-of-the-art DL and image processing methods deliver reliable airway metrics up to the sub-sub-segmental level. Further investigation is needed toward identifying the limiting factors from imaging and analytic perspectives, which are responsible for relatively lower performance of low dose CT-based metrics at peripheral airways.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=12; title_english_function_words=3; title_english_share=0.2500; title_reads=english; abstract_words=399; abstract_english_function_words=119; abstract_english_share=0.2982; abstract_reads=english; language_check=metadata_listed