Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Deep learning model to quantify left atrium volume on routine non-contrast chest CT and predict adverse outcomes

Gilberto J. Aquino; Jordan Chamberlin; Megan K. Mercer; Madison Kocher; Ismail Mikdat Kabakus; Selçuk Akkaya; Matthew J. Fiegel; Sean Brady; Nathan Leaphart; Andrew T. Dippre; Vincent M. Giovagnoli; Basel Yacoub; Athira J Jacob; Mehmet Akif Gulsun; Pooyan Sahbaee; Puneet Sharma; Jeffrey T. Waltz; Uwe Joseph Schoepf; Dhiraj Baruah; Tilman Emrich; Stefan Loy Zimmerman; Michael E. Field; Ali M. Agha; Jeremy R. Burt (2021). Journal of cardiovascular computed tomography

DOI 10.1016/j.jcct.2021.12.005

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low-dose computed tomography (LDCT) are performed routinely for lung cancer screening. However, a large amount of nonpulmonary data from these scans remains unassessed. We aimed to validate a deep learning model to automatically segment and measure left atrial (LA) volumes from routine NCCT and evaluate prediction of cardiovascular outcomes. METHODS: We retrospectively evaluated 273 patients (median age 69 years, 55.5% male) who underwent LDCT for lung cancer screening. LA volumes were quantified by three expert cardiothoracic radiologists and a prototype AI algorithm. LA volumes were then indexed to the body surface area (BSA). Expert and AI LA volume index (LAVi) were compared and used to predict cardiovascular outcomes within five years. Logistic regression with appropriate univariate statistics were used for modelling outcomes. RESULTS: There was excellent correlation between AI and expert results with an LAV intraclass correlation of 0.950 (0.936-0.960). Bland-Altman plot demonstrated the AI underestimated LAVi by a mean 5.86 ​mL/m2. AI-LAVi was associated with new-onset atrial fibrillation (AUC 0.86; OR 1.12, 95% CI 1.08-1.18, p ​< ​0.001), HF hospitalization (AUC 0.90; OR 1.07, 95% CI 1.04-1.13, p ​< ​0.001), and MACCE (AUC 0.68; OR 1.04, 95% CI 1.01-1.07, p ​= ​0.01). CONCLUSION: This novel deep learning algorithm for automated measurement of LA volume on lung cancer screening scans had excellent agreement with manual quantification. AI-LAVi is significantly associated with increased risk of new-onset atrial fibrillation, HF hospitalization, and major adverse cardiac and cerebrovascular events within 5 years.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=3; title_english_share=0.1667; title_reads=english; abstract_words=222; abstract_english_function_words=60; abstract_english_share=0.2703; abstract_reads=english; language_check=metadata_listed