Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Automatic current selection with iterative reconstruction reduces effective dose to less than 1 mSv in low-dose chest computed tomography in persons with normal BMI

Li-Guo Chen; Ping-An Wu; Min-Huei Sheu; Hsing-Yang Tu; Li-Chuan Huang (2019). Medicine

DOI 10.1097/md.0000000000016350

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Abstract Most of the recent studies have used fixed tube current while few investigators use automatic current selection (ACS) with iterative reconstruction (IR) techniques to reduce effective dose (ED) to < 1 mSv in low-dose chest computed tomography (LDCCT). We investigated whether image quality of lungs as produced by a fixed tube current (FTC) of 35 mAs can be maintained with ED < 1 mSv produced by ACS with IR techniques in LDCCT. A total of 32 participants were included. The LDCCT was performed by a FTC 35 mAs (with a kilovoltage peak of 120 kVp) in 16 participants (Group A), and by a DoseRight ACS in 16 participants (Group B). Their images were improved by IR technique. The ED was estimated by multiplying the individual dose length product (DLP) by the dose conversion factor. The image quality was assessed by the CT number, noise levels, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the regions of interest in the apex, upper lobe, and lower lobe of lung regions in the CT images. A t-test was used to evaluate the LDCCT image quality between the groups. The ED was significantly 49.2% lower in Group B than in Group A (0.71 ± 0.05 mSv vs 1.40 ± 0.02 mSv, P < .001). However, noise level, SNR, and CNR were not significantly different between Groups A and B, indicating the image quality was similar between two groups, or our setting parameters for DoseRight ACS with IR technique can achieve the image quality as good as obtained on the FTC 35 mAs with IR techniques. Our results suggest that the DoseRight ACS with IR technique reduces ED to lower than 1 mSv (averagely 0.71 mSv) yet maintains an image quality as good as produced by FTC 35 mAs with IR technique in normal BMI persons. The ACS setup thus is more preferable than the FTC to achieve the ALARA (as low as reasonably achievable) principle.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=24; title_english_function_words=6; title_english_share=0.2500; title_reads=english; abstract_words=308; abstract_english_function_words=119; abstract_english_share=0.3864; abstract_reads=english; language_check=metadata_listed