Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose low-scattering X-ray computed tomography with high-spatial-energy resolutions using a cooled cadmium telluride detector

Hodaka Moriyama; Manabu Watanabe; Shinya Kusachi; Yasuyuki Oda; Eiichi Sato (2019). Ultramicroscopy

DOI 10.1016/j.ultramic.2019.01.014

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

To improve the image quality of photon-counting energy-dispersive X-ray computed tomography (CT) and to reduce the incident dose for the object, we have developed a low-dose low-scattering CT scanner with high-spatial and -energy resolutions using a cooled cadmium telluride (CdTe) detector. X-ray photons are absorbed by the CdTe crystal, and the event pulses from the shaping amplifier are input to a high-speed triple-energy (TE) counter. In the TE-CT, four 3.0-mm-thick lead (Pb) pinholes are used. The line-beam diameter is roughly reduced using the first 2.0-mm-diam pinhole. Using the second 0.5-mm-diam pinhole, the line-beam diameter is reduced again, and the 0.5-mm-diam line beam is exposed to the object. The scattering photon count was reduced using the third 0.5-mm-diam pinhole, and the only penetrating photons are absorbed by the cooled CdTe crystal through the fourth 0.3-mm-diam pinhole for improving the spatial resolution. K-edge tomograms using iodine (I) and gadolinium (Gd) media were obtained simultaneously at two energy ranges of 33-50 and 50-100 keV, respectively. Utilizing I-K-edge CT, coronary arteries filled with I medium were visible. Next, blood vessels filled with Gd medium were observed at high contrasts using Gd-K-edge CT. The maximum count rate was 30 kilocounts per second (kcps) at a tube current of 0.33 mA, and the minimum count rate after penetrating objects was approximately 2 kcps. The maximum incident dose for the object was approximately 0.3 mGy, and the exposure time for TE-CT was 19.6 min at a total rotation angle of 360°. The energy resolution of the detector was 1.1% at 59.5 keV, and the spatial resolutions had values of 0.3 × 0.3 mm2.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=2; title_english_share=0.1053; title_reads=english; abstract_words=277; abstract_english_function_words=89; abstract_english_share=0.3213; abstract_reads=english; language_check=metadata_listed