Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

The feasibility of granzyme B levels using an amperometric immunosensor for lung cancer detection

Jae Heun Chung; Seong Hoon Yoon; Doosoo Jeon; Ho Jung Choi; Kisung Moon; Sun Young Kwon; Heru Agung Saputra; Yun Seong Kim; Yoon‐Bo Shim (2022). Annals of Translational Medicine

DOI 10.21037/atm-22-470

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Low-dose computed tomography (LDCT) has improved the early detection of lung cancer. However, LDCT scans present several disadvantages, including the abundance of false-positive results, which lead to a high socioeconomic cost, psychological burden, and repeated exposure to radiation. Therefore, the identification of complementary biomarkers is needed to select high-risk individuals for LDCT. Here, we showed that granzyme B testing with the novel immunosensor has diagnostic value for identifying patients with lung cancer. Methods: We enrolled 44 patients with lung cancer and 51 health controls at Pusan National University Yangsan Hospital in Korea between March 2018 and September 2019. The immunosensor analyzed serum granzyme B levels, and their association with lung cancer detection was evaluated with machine learning models. Results: Serum granzyme B levels were assessed in samples from patients with lung cancer and healthy individuals. Granzyme B testing showed 100% sensitivity, 80% specificity, and an area under the curve of 0.938 for lung cancer detection. After combining granzyme B testing with clinical predictors such as age, smoking status, or pack-years, results from the five-fold cross-validation with random forest model improved diagnostic accuracy of 92.1%, with a sensitivity, specificity, and area under the curve of 92.0%, 92.1%, and 0.977, respectively. Conclusions: This feasibility study suggested that granzyme B may be utilized to detect lung cancer.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=4; title_english_share=0.2857; title_reads=english; abstract_words=210; abstract_english_function_words=68; abstract_english_share=0.3238; abstract_reads=english; language_check=metadata_listed