Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Multidimensional coordinated attention network for low-dose CT image denoising

Yuyao Luan; Guizhong Fang; Zhiqiong Wang (2025). International Conference on Future of Medicine and Biological Information Engineering (MBIE)

DOI 10.1117/12.3097911

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low Dose Computed Tomography (LDCT) scanning has appeared as a vital healthcare tool to curb the radiation effect on the patient. However, the diagnostic performance of LDCT scanning can be impeded by strong noise and artifacts. However, existing deep learning methods are unable to effectively capture multi-scale feature dependencies and exhibit shortcomings in distinguishing between noise and anatomical structures. To address the challenges, a new Multidimensional Collaborative Attention Network (MDCANet) for denoising LDCT images needs to be introduced. MDCANet uses a tailored encoder-decoder network tailored uniquely for LDCT image denoising applications. Specifically, the encoder of MDCANet houses a unique Dual Attention Layer (DAL), which combines spatial and channel attentions. Spatial attention encompasses local dependencies of each pixel to counter blurring introduced by the image noise. On the other hand, channel attention learns to remove noise by identifying anatomical structures by analyzing the distributions of the channels. At the same time, a Multi-Scale Attention Gate (MSAG) layer is added to the decoder of the network. MSAG uses multi-scale windowing to extract local information at different scales to remove the resolution differences introduced by the noise by preserving higher resolution anatomies. Finally, the concatenated and convoluted output of the processed information obtained from the encoder and the decoder layers provides the final denoised image. Experiments on the American Society of Medical Physics-Mayo Clinic Low-Dose CT Challenge of 2016 dataset illustrate that MDCANet performs outstandingly with metrics of PSNR at 33.7925 dB, SSIM of 0.9195, and RMSE of 8.3655.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=10; title_english_function_words=1; title_english_share=0.1000; title_reads=english; abstract_words=248; abstract_english_function_words=83; abstract_english_share=0.3347; abstract_reads=english; language_check=metadata_listed