Multidimensional coordinated attention network for low-dose CT image denoising
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Low Dose Computed Tomography (LDCT) scanning has appeared as a vital healthcare tool to curb the radiation effect on the patient. However, the diagnostic performance of LDCT scanning can be impeded by strong noise and artifacts. However, existing deep learning methods are unable to effectively capture multi-scale feature dependencies and exhibit shortcomings in distinguishing between noise and anatomical structures. To address the challenges, a new Multidimensional Collaborative Attention Network (MDCANet) for denoising LDCT images needs to be introduced. MDCANet uses a tailored encoder-decoder network tailored uniquely for LDCT image denoising applications. Specifically, the encoder of MDCANet houses a unique Dual Attention Layer (DAL), which combines spatial and channel attentions. Spatial attention encompasses local dependencies of each pixel to counter blurring introduced by the image noise. On the other hand, channel attention learns to remove noise by identifying anatomical structures by analyzing the distributions of the channels. At the same time, a Multi-Scale Attention Gate (MSAG) layer is added to the decoder of the network. MSAG uses multi-scale windowing to extract local information at different scales to remove the resolution differences introduced by the noise by preserving higher resolution anatomies. Finally, the concatenated and convoluted output of the processed information obtained from the encoder and the decoder layers provides the final denoised image. Experiments on the American Society of Medical Physics-Mayo Clinic Low-Dose CT Challenge of 2016 dataset illustrate that MDCANet performs outstandingly with metrics of PSNR at 33.7925 dB, SSIM of 0.9195, and RMSE of 8.3655.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=10; title_english_function_words=1; title_english_share=0.1000; title_reads=english; abstract_words=248; abstract_english_function_words=83; abstract_english_share=0.3347; abstract_reads=english; language_check=metadata_listed