Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

LDCT-MOSNet: A Lightweight Multi-Organ Segmentation Model for Low-Dose CT Via Cascaded DenseASPP and Dynamic Boundary-Aware Learning

Yanglin Wang; Zongqi Xu; Fuge Yang; Yang Xie; Chengjie Li; Tao Chen; Zhuoxuan An; Chongyang Wang (2025). IEEE International Conference on Bioinformatics and Biomedicine (BIBM)

DOI 10.1109/bibm66473.2025.11357154

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (LDCT) has emerged as a critical modality for lung cancer screening and thoracic disease diagnosis, offering significantly reduced radiation risk while maintaining high-resolution thin-slice imaging capabilities. However, multi-organ segmentation in LDCT presents three major challenges: substantial scale variation among organs, boundary ambiguity, and extreme class imbalance. To address the inherent limitations of DeepLabV3, we propose the LDCTMOSNet framework with three key innovations: First, the cascaded DenseASPP module constructed via densely connected multi-dilation-rate atrous convolutions achieves continuous receptive field coverage, eliminating scale blind spots in conventional ASPP. Second, the cross-layer feature reuse mechanism that integrates shallow edge textures, mid-level anatomical structures, and deep semantic context to establish high-resolution, semantically compatible feature representations. Third, the proposed LDCTloss compound function, combining dynamic edge awareness and multi-scale confidence weighting, enhances boundary precision while maintaining inter-class balance. Experimental results demonstrate that our framework achieves 97.11% mDice with only 8.87M parameters on a multicenter LDCT dataset (2,000 scans with 29 organ labels), outperforming nnU-Net (94.55%) and SwinTransformer (92.34%), while reducing boundary error (HD) to 1.46mm (85.2% improvement). Ablation studies confirm the synergistic necessity of the three proposed modules. Generalization tests on LIDC lung cancer segmentation (95.24% mDice) and TCIA pulmonary nodule segmentation (95.30%) validate the architecture's robustness. This study delivers a high-precision, lightweight solution for multi-organ segmentation on 16-slice LDCT devices in primary hospitals. The implementation will be available at https://github.com/codemaster-XU/LDCT-MOSNet.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=3; title_english_share=0.1500; title_reads=english; abstract_words=241; abstract_english_function_words=49; abstract_english_share=0.2033; abstract_reads=english; language_check=metadata_listed