Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

4D-CT Hyper-Elastography Using a Biomechanical Model

Dayton Miranda; Parya Jafari; Sergio C. H. Dempsey; Abbas Samani (2020). Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)

DOI 10.1109/embc44109.2020.9176432

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low dose computed tomography (LDCT) is the current gold-standard for lung cancer diagnosis. However, accuracy of diagnosis is limited by the radiologist's ability to discern cancerous from non-cancerous nodules. To assist with diagnoses, a 4D-CT lung elastography method is proposed to distinguish nodules based on tissue stiffness properties. The technique relies on a patient-specific inverse finite element (FE) model of the lung solved using an optimization algorithm. The FE model incorporates hyperelastic material properties for tumor and healthy regions and was deformed according to respiration physiology. The tumor hyperelastic parameters and trans-pulmonary pressure were estimated using an optimization algorithm that maximizes similarity between the actual and simulated tumor and lung image data. The proposed technique was evaluated using an in-silico study where the lung tumor elastic properties were assumed. Following that evaluation, the technique was applied to clinical 4D-CT data of two lung cancer patients. Results from the evaluation study show that the elastography technique recovered known tumor parameters with only 6% error. Tumor hyperelastic properties from the clinical data are also reported. Results from this proof of concept study demonstrate the ability to perform lung elastography with 4D-CT data alone. Advancements in the technique could lead to improved diagnoses and timely treatment of lung cancer.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=8; title_english_function_words=1; title_english_share=0.1250; title_reads=english; abstract_words=214; abstract_english_function_words=71; abstract_english_share=0.3318; abstract_reads=english; language_check=metadata_listed