Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Advancements in monitoring paranasal sinuses among people with cystic fibrosis using photon-counting CT
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background People diagnosed with cystic fibrosis (pwCF) who have chronic rhinosinusitis undergo low-dose computed tomography (LDCT) scans of the paranasal sinuses as a crucial component of their disease management. Purpose To assess and compare the intra-individual image quality and radiation dose between photon-counting CT (PCCT) and CT scanners utilizing an energy-integrating detector system (EID-CT) with LD protocols for pwCF. Material and Methods In this retrospective study, 23 pwCF who underwent LD paranasal sinuses PCCT and who had previously undergone LD paranasal sinuses EID-CT were included. An intra-individual comparison of image quality and radiation dose was carried out. Three blinded radiologists rated overall image quality, image sharpness, and image noise using a 5-point Likert scale. The study measured the dose length product, the volumetric CT dose index, the effective dose, and the signal to noise ratio (SNR). Results The cohort comprised 23 individuals (6 women [26%], 17 men [74%]; mean age = 36.7 years). PCCT achieved superior evaluations for image quality in comparison to EID-CT (mean = 5 vs. 3; P <0.001). Furthermore, PCCT exhibited diminished image noise (mean = 4 vs. 3; P <0.001). The mean SNR of the paranasal sinuses demonstrated an increase in PCCT as opposed to EID-CT ( P <0.001). PCCT demonstrated a reduction of approximately 36% in effective dose compared to EID-CT (mean = 0.09 vs. 0.15 mSv; P <0.001). Conclusion PCCT scans of the paranasal sinuses offer superior image quality and substantially reduce radiation dose compared to EID-CT scans in pwCF, offering a safer and more effective imaging alternative compared to EID-CT for managing cystic fibrosis.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=250; abstract_english_function_words=64; abstract_english_share=0.2560; abstract_reads=english; language_check=metadata_listed