Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Pilot Multireader Study of Next Generation Chest X-ray Tomosynthesis for the Detection of Lung Cancer
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Abstract RATIONALE Lung cancer screening (LCS) with annual low-dose computed tomography (LDCT) decreases mortality by identifying early-stage cancer but uptake is limited, especially in medically under-resourced areas. Chest x-ray tomosynthesis (CXRT) is an alternative imaging approach that can be manufactured at one sixth the cost of CT but has shown limited potential for lung cancer detection in prior studies. We investigated a novel, mobile CXRT device designed to overcome limitations of prior devices in a multireader pilot study of its performance in a composite population of patients undergoing LDCT, enriched with patients undergoing diagnostic chest CT for new lung cancer and suspicious lung nodules. METHODS: A composite population of patients undergoing screening and diagnostic chest CT between October 2023 and May 2024 were prospectively recruited to undergo imaging with next-generation CXRT device. Excluding subjects recruited for operator training, dose optimization, and radiologist training, 65 were included in a multireader study. Four subspecialty-trained cardiothoracic radiologists independently evaluated CXRT images for pulmonary lesions, blinded to patient data and CT scans. Two prespecified sets of analysis were performed to assess the accuracy of CXRT for detection of 1) biopsy-confirmed cancer and 2) pulmonary nodules on CT with ≥10 mm, ≥8 mm, and ≥6 mm long-axis size thresholds. RESULTS: Of the 65 subjects recruited for the multireader study, 20 had biopsy-proven malignancy on follow-up (median 262 days, maximum 343 days, minimum 146 days) while the remaining had benign exams. Readers showed substantial concordance (κ= 0.44-0.69) for detection of malignancy (N=20) with high sensitivity (0.85-1.0) and moderate specificity (0.56-0.60). There was moderate-high sensitivity for nodules, most of which were benign, across nodule size thresholds ≥10 mm (N=31, Sn 0.65-0.90, Sp 0.74-0.91), ≥8 mm (N=36, Sn 0.61-0.86, Sp 0.72-0.83), and ≥6 mm (N=41, Sn 0.66-0.85, Sp 0.67-0.79). CONCLUSIONS: This is the first human trial of a novel next-generation CXRT device, conducted in an at-risk pilot population enriched with participants with suspected or recurrent lung cancer. The high sensitivity of CXRT for detecting lung cancer signals its potential future use as a first-line LCS tool whereby positive screens would be referred for diagnostic CT. Notably, false negative rates with LDCT have been estimated to be 8-15% based on retrospective analysis of large LCS trials. The current multireader trial demonstrates the feasibility of CXRT for lung cancer detection and sets initial performance benchmarks to inform future studies and efforts at optimization.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=16; title_english_function_words=4; title_english_share=0.2500; title_reads=english; abstract_words=381; abstract_english_function_words=116; abstract_english_share=0.3045; abstract_reads=english; language_check=metadata_listed