Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Visual grading evaluation of reconstruction methods and dose optimisation in abdominal Computed Tomography
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
Since its introduction in the 1970's CT has emerged as a modality of choice because of its high sensitivity in producing accurate diagnostic images.A third of all Computed Tomography (CT) examinations are abdominal CTs which deliver one of the highest doses among common examinations.An increase in the number of CT examinations has raised concerns about the negative effects of ionising radiation as the dose is cumulative over the life span of the individual.Image quality in CT is closely related to the radiation dose, so that a certain dose with an associated small, but not negligible, risk is a prerequisite for high image quality.Typically, dose reduction in CT results in higher noise and a decrease in low contrast resolution which can be detrimental to the image quality produced.New technology presents a wide range of dose reduction strategies, the latest being iterative reconstruction (IR).The aim of this thesis was to evaluate two different classes of iterative reconstruction algorithms: statistical (SAFIRE) and model-based (AD-MIRE) as well as to explore the diagnostic value of a low-dose abdominal CT for optimisation purposes.This thesis included a total of 140 human subjects in four image quality evaluation studies, three of which were prospective studies (Papers I, II and IV) and one retrospective study (Paper III).Visual grading experiments to determine the potential dose reductions, were performed with pairwise comparison of image quality in the same patient at different tube loads (dose) and reconstructed with Filtered back projection (FBP) and SAFIRE strength 1 in a low-dose abdominal CT (Paper I) and FBP and ADMIRE strengths 3 and 5 in a standard dose abdominal CT (Paper II).Paper IV evaluated the impact of slice thicknesses in CT images reconstructed with ADMIRE strengths 3 and 5 when comparing multiplanar reconstruction (MPR) formatted images in a standard dose abdominal CT.Paper III, on the other hand, was an absolute assessment of image quality and pathology between the three phases of a CT Urography (CTU) protocol to explore the diagnostic value of low-dose abdominal CT.The anonymised images were displayed in random order and image quality was assessed by a group of radiologists using image quality criteria from the "European guidelines of quality criteria for CT".The responses from the reviewer assessment were analysed statistically with ordinal logistic regression i.e.Visual Grading Regression (VGR).Results in Paper I show that a small dose reduction (5-9 %) was possible using SAFIRE strength 1 and indicated the need for further research to LIST OF PAPERSThis thesis is based on the following papers, referred to in the text by their roman numerals (I-IV). I. Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and Filtered back projection.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=453; abstract_english_function_words=165; abstract_english_share=0.3642; abstract_reads=english; language_check=metadata_listed