Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Coronary Artery Calcium Scoring with Photon-Counting Detector CT: Ultra-Low-Dose Scan Versus Coronary CT Angiography-Derived Images

Suguru Araki; Satoshi Nakamura; Mana Deguchi; Akio Yamazaki; Shintaro Yamaguchi; Naoki Hashimoto; Takanori Kokawa; Masafumi Takafuji; Yasutaka Ichikawa; Hajime Sakuma; Kakuya Kitagawa (2026). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2026.08.002

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

PURPOSE: To compare coronary artery calcium (CAC) scores from ultra-low-dose true non-contrast (TNC), virtual non-contrast (VNC), and virtual non-iodine (VNI) images with standard TNC on a dual-source photon-counting detector CT (PCD-CT). METHODS: In this prospective single-center study (January 2025-March 2026), patients underwent standard TNC (sequential, 120 kVp), ultra-low-dose TNC (high-pitch helical, tin-filtered 100 kVp), and coronary CT angiography (CCTA); VNC and VNI images were generated from CCTA. CAC scores and burden categories were evaluated. Correlation and agreement with standard TNC were assessed using Pearson coefficients with Williams' test, Bland-Altman plots, and weighted Cohen's kappa. RESULTS: Seventy-one patients (median age, 75 years; 52 men) were evaluated. Median dose-length product was 7.98, 71.8, and 428 mGy cm for ultra-low-dose TNC, standard TNC, and CCTA, respectively. Ultra-low-dose TNC showed the strongest correlation with standard TNC (r = 0.996), superior to VNI (r = 0.976, P < 0.001) and VNC (r = 0.900, P < 0.001). Agreement in CAC burden categorization was excellent for ultra-low-dose TNC (κ = 0.932) and good for VNI (κ = 0.827), whereas VNC showed moderate agreement (κ = 0.424). VNI had minimal bias (mean difference, -3.9) but wider limits of agreement than ultra-low-dose TNC (-356.5 to 348.6 vs. -163.2 to 105.9). VNC underestimated CAC scores (mean bias, -442.0). CONCLUSION: Ultra-low-dose TNC with dual-source PCD-CT showed excellent agreement with standard TNC while reducing radiation by nearly 90%. VNI was acceptable but less robust, whereas VNC substantially underestimated CAC scores. Ultra-low-dose TNC is a reliable, dose-efficient alternative to standard TNC for CAC scoring.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=1; title_english_share=0.0526; title_reads=not_english; abstract_words=253; abstract_english_function_words=51; abstract_english_share=0.2016; abstract_reads=english; language_check=metadata_listed