Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Noninvasive cerebral perfusion imaging technology based on low-dose radiation computed tomography angiography and hemodynamic simulation

Zijie Wang; Youjun Liu; Liyuan Kong; Hao Sun; Huanmei Guo; Liyuan Zhang; Yanjun Gong; Bao Li (2026). Elsevier BV

DOI 10.2139/ssrn.6793374

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Background and Objective: Computed tomography perfusion imaging is widely used for cerebral perfusion assessment but is limited by high radiation exposure and complex post-processing procedures. This study aimed to develop a low-radiation computational approach for noninvasive cerebral perfusion estimation using cerebral computed tomography angiography data combined with hemodynamic modeling.Methods: A patient-specific multiscale computational framework was developed to estimate cerebral tissue perfusion from computed tomography angiography images. Small arteries and arterioles were reconstructed using an angiogenesis-based optimization algorithm. Arterial blood flow velocity distribution was assigned according to allometric scaling laws, and outlet flow rates were determined based on hemodynamic principles. A three-dimensional brain tissue model coupled with a convection–diffusion equation was used to simulate cerebral perfusion. Quantitative validation was performed by comparing simulated perfusion results with clinical computed tomography perfusion measurements in both healthy individuals and patients with cerebral arterial stenosis. Model accuracy was evaluated using root mean square error and mean squared error metrics.Results: The angiogenesis-based vascular reconstruction algorithm demonstrated high accuracy, with root mean square errors of 0.17% and 3.49% compared with clinical vascular data. Simulated cerebral perfusion showed strong agreement with clinical perfusion imaging results. The average mean squared error between simulated and clinical perfusion data was 5.78% in healthy individuals and 9.73% in patients with cerebral arterial stenosis. The proposed framework achieved rapid and quantitatively accurate cerebral perfusion estimation under low-radiation imaging conditions.Conclusions: The proposed computed tomography angiography-based computational method enables fast, accurate, and low-radiation cerebral perfusion assessment without relying on conventional perfusion imaging workflows. This framework provides a promising alternative for patient-specific cerebral perfusion evaluation and may support future applications in ischemic cerebrovascular disease assessment and computational neurovascular analysis.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=16; title_english_function_words=2; title_english_share=0.1250; title_reads=english; abstract_words=283; abstract_english_function_words=66; abstract_english_share=0.2332; abstract_reads=english; language_check=metadata_missing