Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Diagnostic accuracy of deep learning-assisted low-dose CT screening for lung cancer detection: a systematic review and meta-analysis
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: Deep learning (DL)-assisted low-dose computed tomography (LDCT) may improve lung cancer screening, but the available evidence is heterogeneous and patient-level diagnostic accuracy remains uncertain. METHODS: MEDLINE, Embase, and Web of Science were searched from January 2010 to December 2025 for studies evaluating DL-assisted LDCT in lung cancer screening or screening-relevant populations. Two reviewers independently screened studies, extracted data, and assessed risk of bias using QUADAS-2. AI-specific reporting completeness was assessed descriptively using items adapted from CLAIM and STARD-AI. Studies with complete or reconstructible patient-level 2 × 2 data at a defined threshold were pooled using bivariate random-effects and hierarchical summary receiver operating characteristic models. Studies without sufficient threshold-specific data were synthesised narratively. RESULTS: Eleven studies met the inclusion criteria. Five studies, comprising 2,220 participants, 232 lung cancer cases, and 1,988 non-cases, provided usable threshold-specific 2 × 2 data and were included in the meta-analysis. Six studies were synthesised narratively because patient-level TP, FP, FN, and TN values were unavailable or not reconstructible. Pooled sensitivity was 85.4% (95% CI, 79.1-90.0), and pooled specificity was 83.5% (95% CI, 73.5-90.2). The positive likelihood ratio was 5.17, the negative likelihood ratio was 0.18, and the diagnostic odds ratio was 29.53. No study was at low risk of bias across all QUADAS-2 domains, and AI-specific reporting gaps were common. Subgroup, meta-regression, and sensitivity analyses were not feasible because only five studies were quantitatively eligible. No statistical evidence of small-study effects was detected, although this assessment was inconclusive because only five studies were pooled. CONCLUSIONS: DL-assisted LDCT shows promising but preliminary diagnostic accuracy for lung cancer screening. However, the small, heterogeneous, and methodologically limited evidence base does not support autonomous clinical use. DL is currently best considered a decision-support tool within radiologist-led screening pathways, pending prospective external validation and workflow-based evaluation.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=20; title_english_function_words=4; title_english_share=0.2000; title_reads=english; abstract_words=297; abstract_english_function_words=80; abstract_english_share=0.2694; abstract_reads=english; language_check=metadata_listed