Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Evaluation with low-dose dual-phase helical computed tomography of patients with thyroid lesions
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
BackgroundThe incidence of thyroid cancer has been increasing. Our aim was to evaluate the efficacy of low-dose dualphase helical computed tomography (CT) in the characterization of thyroid lesions, and to discuss the relationship between image characteristics and their pathology.MethodsOne hundred and six patients with thyroid lesions underwent low-dose dual-phase helical CT after the injection of contrast material. CT scans were obtained at arterial and venous phase with delays of 25 and 65 seconds, and tube current of 60 and 120 mA, respectively. The attenuation change in the lesion between the arterial and venous phase was analyzed and categorized as “increased,” “decreased,” “mixed” or “no change.”ResultsHistopathologic diagnosis was obtained by surgery in 106 patients (115 lesions). Of the 106 patients, 45 had nodular goiter, 5 thyroid adenoma, 6 thyroiditis, and 50 papillary thyroid carcinoma (PTC) (59 lesions). The attenuation value showed a significant difference (P<0.05) between the arterial and venous phase for the high attenuation area. There was statistical significant difference in terms of attenuation value in high attenuation areas at both phases and in low attenuation areas on arterial phase between nodular goiter and PTC (P<0.05). However, there was no significant difference in attenuation value between adenoma and PTC. Twenty-nine cases (76.3%) of goiter manifested mixed type, 3 cases (3/5) of adenoma showed decreased type, 6 cases (6/6) of thyroiditis showed increased type, and 55 cases (93.2%) of PTC showed decreased type attenuation. The sensitivity, specificity for thyroid carcinoma by dual-phase CT were 94.9% and 80.4% respectively. The overall diagnostic accuracy for thyroid lesions by dual-phase CT was 87.8%.ConclusionsThe performance of dual-phase helical CT is related to the pathological structure of the lesions. The analysis of enhancement patterns by using dual-phase helical CT will be helpful in the differential diagnosis of thyroid lesions.
From Crossref.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=284; abstract_english_function_words=101; abstract_english_share=0.3556; abstract_reads=english; language_check=metadata_listed