Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Transformer-Augmented Generative Adversarial Networks for Multi-Modal Super-Resolution in Lowdose CT Imaging
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Low-dose computed tomography is commonly employed to mitigate patient radiation exposure. However, it generates imagery with heightened levels of noise and a deterioration in fine-scaled anatomical detail, leading to reduced diagnostic confidence. Methods conventionally used for either denoising or interpolation can suppress noise while tending to blur critical structures-particularly in regions of subtle pathology. Recently developed techniques using generative adversarial networks have shown great promise in reconstructing high-quality images from degraded inputs. However, many fail to capture longrange dependencies that are crucial for the recovery of structural details. In this work, we introduce a Transformer-Augmented Generative Adversarial Network (TA-GAN) that combines convolutional layers for local feature extraction along with multihead self-attention modules for global context modeling. The generator utilizes a hybrid attention mechanism that embeds spatial, channel, and cross-modal attention, thereby offering the model the capability to emphasize diagnostically relevant regions while preserving structural integrity. The TA-GAN demonstrated significant PSNR and SSIM improvements over state-of-the-art GAN-based super-resolution methods while yielding higher lesion conspicuity and confidence scores in clinical reader studies performed on the LIDC-IDRI and Mayo Clinic LDCT datasets. Our results demonstrate the feasibility of Transformer-driven architectures in bringing about improvements in low-dose CT reconstruction and provide a way to safer imaging without compromising diagnostic accuracy.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=223; abstract_english_function_words=66; abstract_english_share=0.2960; abstract_reads=english; language_check=metadata_listed