Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Feasibility of electromagnetic navigation bronchoscopy-guided lung resection for pulmonary ground-glass opacity nodules
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: Recent advances in imaging modalities and recommended low-dose computed tomography screening programs have made it easier to diagnose early lung cancer. However, the diagnosis of small ground-glass nodules (GGNs) has been problematic due to inappropriate specimen procurement and failure of conventional percutaneous core needle biopsy. Thus, we aimed to evaluate the usefulness of electromagnetic navigation bronchoscopy (ENB)-guided video-assisted lung resection for not only the diagnosis but also treatment of GGNs. METHODS: From 2017 to 2019, 110 patients with suspicious lung cancer lesions that were not diagnosed by conventional procedure underwent ENB-guided lung resection. Among 35 cases of GGNs, 33 cases of localization were included in this study (two cup biopsy cases were excluded). We used SuperDimension™ for the ENB procedure. After general anesthesia, indigo carmine (0.3-0.5 mL) was injected, and GGNs were resected through video-assisted thoracoscopic surgery. RESULTS: Of the 33 GGNs, 16 were pure (2 adenocarcinomas in situ, 5 minimally invasive adenocarcinomas (MIAs), 3 adenocarcinomas, and 6 benign lesions) and 17 were mixed (1 MIA, 11 adenocarcinomas, and 5 benign lesions). The mean size of all lesions was 11.2±7.78 mm, mean distance to the pleura was 11.2±14.2 mm, and mean ENB procedure time was 18.8±8.88 minutes. Dye localization and surgical resection of GGN were successful in all cases. There was no procedure-related complication. CONCLUSIONS: ENB is a feasible and highly accurate localization method for minimally invasive lung resection of small GGNs.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=221; abstract_english_function_words=74; abstract_english_share=0.3348; abstract_reads=english; language_check=metadata_listed