Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

CGLC-Net: A Collaborative Global-Local Context Network for Medical Low-Dose CT Images Denoising

Zhang Fangge; Ping-Ping Gu; Qingfeng Wu (2026). International Conference on Computer Supported Cooperative Work in Design (CSCWD)

DOI 10.1109/cscwd68734.2026.11582615

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-Dose Computed Tomography (LDCT) plays a vital role in minimizing patient radiation exposure, but it introduces severe noise and artifacts that degrade image quality and compromise diagnostic accuracy. Existing deep learning-based denoising methods, dominated by Convolutional Neural Networks (CNNs) and Transformers, struggle to simultaneously capture local features and model global context while maintaining linear computational complexity. To solve these problems, we propose a Collaborative Global-Local Context Network (CGLC-Net) for medical low-dose CT image denoising. The core of the network is an innovative Collaborative Global-Local Context Block (CGLC Block), which consists of three parallel branches specifically designed to enhance multi-scale feature representation. These include a Global Context Scanner Branch based on the Position-Enhanced Mamba Block (PEMB) for efficient modeling of long-range dependencies, a Salient Feature Extractor Branch for emphasizing dominant structural information, and a Local Context Extraction Branch for extracting local features. Additionally, we introduce the Multi-scale Feature Fusion Attention Module (MFFAM) to integrate features of different scales, further enhancing multi-scale context aggregation. Experimental results demonstrate that the proposed CGLC-Net achieves superior performance compared to state-of-the-art methods in both quantitative metrics and visual quality, effectively suppressing noise while excellently preserving critical anatomical structures.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=207; abstract_english_function_words=47; abstract_english_share=0.2271; abstract_reads=english; language_check=metadata_listed