Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Automatic Coronary Calcium Scoring in Low-Dose Chest Computed Tomography

I. Isgum; M. Prokop; M. Niemeijer; M. A. Viergever; B. van Ginneken (2012). IEEE Transactions on Medical Imaging

DOI 10.1109/tmi.2012.2216889

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

The calcium burden as estimated from non-ECG-synchronized computed tomography (CT) exams acquired in screening of heavy smokers has been shown to be a strong predictor of cardiovascular events. We present a method for automatic coronary calcium scoring with low-dose, non-contrast-enhanced, non-ECG-synchronized chest CT. First, a probabilistic coronary calcium map was created using multi-atlas segmentation. This map assigned an a priori probability for the presence of coronary calcifications at every location in a scan. Subsequently, a statistical pattern recognition system was designed to identify coronary calcifications by texture, size, and spatial features; the spatial features were computed using the coronary calcium map. The detected calcifications were quantified in terms of volume and Agatston score. The best results were obtained by merging the results of three different supervised classification systems, namely direct classification with a nearest neighbor classifier, and two-stage classification with nearest neighbor and support vector machine classifiers.We used a total of 231 test scans containing 45,674 mm³ of coronary calcifications. The presented method detected on average 157/198 mm³ (sensitivity 79.2%) of coronary calcium volume with on average 4 mm false positive volume. Calcium scoring can be performed automatically in low-dose, non-contrast enhanced, non-ECG-synchronized chest CT in screening of heavy smokers to identify subjects who might benefit from preventive treatment.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=10; title_english_function_words=1; title_english_share=0.1000; title_reads=english; abstract_words=218; abstract_english_function_words=66; abstract_english_share=0.3028; abstract_reads=english; language_check=metadata_missing