Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Automated Fast Prediction of Bone Mineral Density From Low-dose Computed Tomography

Kun Zhou; Enhui Xin; Shan Yang; Xiao Luo; Yuqi Zhu; Yanwei Zeng; Junyan Fu; Zhuoying Ruan; Rong Wang; Daoying Geng; Liqin Yang (2025). Academic Radiology

DOI 10.1016/j.acra.2025.02.041

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low-dose chest CT (LDCT) is commonly employed for the early screening of lung cancer. However, it has rarely been utilized in the assessment of volumetric bone mineral density (vBMD) and the diagnosis of osteoporosis (OP). PURPOSE: This study investigated the feasibility of using deep learning to establish a system for vBMD prediction and OP classification based on LDCT scans. METHODS: This study included 551 subjects who underwent both LDCT and QCT examinations. First, the U-net was developed to automatically segment lumbar vertebrae from single 2D LDCT slices near the mid-vertebral level. Then, a prediction model was proposed to estimate vBMD, which was subsequently employed for detecting OP and osteopenia (OA). Specifically, two input modalities were constructed for the prediction model. The performance metrics of the models were calculated and evaluated. RESULTS: The segmentation model exhibited a strong correlation with manual segmentation, achieving a mean Dice similarity coefficient (DSC) of 0.974, sensitivity of 0.964, positive predictive value (PPV) of 0.985, and Hausdorff distance of 3.261 in the test set. Linear regression and Bland-Altman analysis demonstrated strong agreement between the predicted vBMD from two-channel inputs and QCT-derived vBMD, with a root mean square error of 8.958 mg/mm3 and an R2 of 0.944. The areas under the curve for detecting OP and OA were 0.800 and 0.878, respectively, with an overall accuracy of 94.2%. The average processing time for this system was 1.5 s. CONCLUSION: This prediction system could automatically estimate vBMD and detect OP and OA on LDCT scans, providing great potential for the osteoporosis screening.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=251; abstract_english_function_words=90; abstract_english_share=0.3586; abstract_reads=english; language_check=metadata_listed