Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Raw-data-based iterative reconstruction versus filtered back projection: image quality of low-dose chest computed tomography examinations in 87 patients

Haiyan Wang; Bingyi Tan; Bin Zhao; Changhu Liang; Zhuodong Xu (2013). Clinical Imaging

DOI 10.1016/j.clinimag.2013.06.004

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

OBJECTIVE: The objective was to compare standard-dose chest computed tomography (CT) reconstructed with filtered back projection (FBP) versus low-dose images with FBP and raw-data-based iterative reconstruction. METHODS: Eighty-seven consecutive patients (46 male; mean age, 54.54 ± 16.12; mean body mass index, 24.58 ± 4.07) referred for initial chest CT with full-dose examinations [mean dose-length product (DLP), 183.37 ± 44.13 mGy · cm] and follow-up chest CT with half-dose examinations (mean DLP, 91.08 ± 23.81 mGy · cm) were included. The full-dose protocol was reconstructed with FBP; the half-dose protocol was reconstructed with FBP and sinogram-affirmed iterative reconstruction (SAFIRE). Noise and signal-to-noise ratio were compared using a paired Student's t test; subjective image quality and lesion conspicuity were compared using Wilcoxon signed ranks test. RESULTS: Actual radiation dose of follow-up CT was about 50% (49.26% ± 2.62%) of standard-dose protocol. Compared to full-dose images with FBP, there was no significant difference in half-dose images with SAFIRE in the objective noise (ascending aorta: P=.38, descending aorta: P=.70, trachea on mediastinal images: P=.37) and SNR (ascending aorta: P=.14, descending aorta: P=.72, trachea on mediastinal images: P=.06) on mediastinal images. Noise was significantly lower (P<.001) and SNR was significantly higher (P<.001) in half-dose images with SAFIRE on lung images. Noise was significantly higher (P<.001) and SNR was significantly lower (P<.001) in half-dose images with FBP. Subjective image quality was similar on both mediastinal images (P=.317) and lung images (P=.614) of half-dose SAFIRE images versus full-dose FBP images. Lesion conspicuity was also similar. Subjective image quality was significantly lower on both mediastinal images (P<.001) and lung images (P<.001) of half-dose FBP images versus full-dose FBP images. The conspicuity of some lesions was significantly lower (ground-glass opacity, P<.0001; ill-defined micronodule, P<.0001; lung cyst, P<.0001; emphysematous lesion, P=.003) on half-dose FBP versus full-dose FBP images. CONCLUSION: Compared to full-dose CT images reconstructed with the conventional FBP algorithm, SAFIRE with three iterations could provide similar or better image quality at 50% less dose.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=2; title_english_share=0.1000; title_reads=english; abstract_words=335; abstract_english_function_words=75; abstract_english_share=0.2239; abstract_reads=english; language_check=metadata_listed