Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Identification of circulating tumor cells using 4‐color fluorescence in situ hybridization: Validation of a noninvasive aid for ruling out lung cancer in patients with low‐dose computed tomography–detected lung nodules

Ruth L. Katz; Tanweer M. Zaidi; Deep Kiritbhai Pujara; Namita D. Shanbhag; Duy Truong; Shekhar Patil; Reza John Mehran; Randa A. El‐Zein; Sanjay S. Shete; Joshua David Kuban (2020). Cancer Cytopathology

DOI 10.1002/cncy.22278

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Approximately one third of needle biopsies that are performed to rule out malignancy of indeterminate pulmonary nodules detected radiologically during lung cancer screening are negative, thus exposing cancer-free patients to risks of pneumothorax, bleeding, and infection. A noninvasive confirmatory tool (eg, liquid biopsy) is urgently needed in the lung cancer diagnosis setting to stratify patients who should receive biopsy versus those who should be monitored. METHODS: A novel antigen-independent, 4-color fluorescence in situ hybridization (FISH)-based method was developed to detect circulating tumor cells (CTCs) with abnormalities in gene copy numbers in mononuclear cell-enriched peripheral blood samples from patients with (n = 107) and without (n = 100) lung cancer. RESULTS: Identification of CTCs using FISH probes at 10q22.3/CEP10 and 3p22.1/3q29 detected lung cancer cases with 94.2% accuracy, 89% sensitivity, and 100% specificity compared with biopsy. CONCLUSION: The high accuracy of this liquid biopsy method suggests that it may be used as a noninvasive decision tool to reduce the frequency of unnecessary needle biopsy in patients with benign pulmonary lesions.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=31; title_english_function_words=7; title_english_share=0.2258; title_reads=english; abstract_words=169; abstract_english_function_words=53; abstract_english_share=0.3136; abstract_reads=english; language_check=metadata_listed