Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Assessment of Low-Dose Computed Tomography Protocols in Reducing Radiation Exposure without Compromising Diagnostic Yield in Pulmonary Nodule Detection

Amirah Fahad Alshammeri (2026). Journal of Pioneering Medical Sciences

DOI 10.47310/jpms2026150227

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Pulmonary nodules are often the earliest radiological markers of lung cancer and their timely detection is essential for improving survival outcomes. While Computed Tomography (CT) remains the gold standard for nodule detection, concerns regarding cumulative radiation exposure have led to increasing use of Low-Dose Computed Tomography (LDCT). Objective: This study aimed to assess whether LDCT protocols can effectively reduce radiation exposure without compromising diagnostic yield in pulmonary nodule detection. Methodology: This cross-sectional analytical study was conducted in the Department of Radiology at Hail city from Jan 2025 to July 2025, including 75 patients aged ≥18 years who underwent CT chest for pulmonary nodule evaluation. Each patient received both standard-dose CT and LDCT protocols. Radiation dose was recorded in millisieverts (mSv) and two blinded radiologists independently reviewed the scans for presence, size and type of nodules. Standard-dose CT served as the reference standard. Results: The mean radiation dose for standard CT was 6.8±1.2 mSv, while LDCT reduced exposure to 1.9±0.5 mSv, representing a 72% dose reduction (p<0.001). Pulmonary nodules were identified in 41 patients (54.7%) on standard CT and in 39 patients (52.0%) on LDCT. The sensitivity, specificity, positive predictive value and negative predictive value of LDCT were 95.1, 94.1, 95.1 and 94.1%, respectively. LDCT successfully detected all clinically significant nodules ≥6 mm, though it missed two sub-5 mm ground-glass nodules. Inter-observer agreement was excellent for both standard CT (κ = 0.92) and LDCT (κ = 0.89). Conclusion: LDCT significantly reduces radiation exposure while preserving high diagnostic accuracy in pulmonary nodule detection. Although its sensitivity for very small ground-glass nodules is slightly limited, LDCT demonstrates equivalent performance to standard CT for clinically relevant nodules, supporting its use in lung cancer screening and surveillance protocols.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=19; title_english_function_words=4; title_english_share=0.2105; title_reads=english; abstract_words=272; abstract_english_function_words=77; abstract_english_share=0.2831; abstract_reads=english; language_check=metadata_missing