Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

[11C]Elacridar as a novel P-glycoprotein PET tracer, assessment of whole-body distribution and radiation dosimetry in humans

Martin Bauer; Markus Alexander Zeitlinger; Georg Dobrozemsky; Cécile Philippe; Markus Müller; Oliver Langer (2011). BMC Pharmacology

DOI 10.1186/1471-2210-11-s2-a46

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

The ATP-binding cassette transporter P-glycoprotein (P-gp) is expressed at the blood-brain barrier (BBB) where it protects the brain from toxic substances and xenobiotics by active efflux transport. The C-labelled third-generation P-gp inhibitor [ C]elacridar was developed as a positron emission tomography (PET) tracer for the in vivo quantification of P-gp expression levels in different organs. The aim of this study was to provide human dosimetry estimates for [ C]elacridar based on whole-body PET. Whole-body low dose computed tomography (CT) and dynamic and static whole-body PET scans were acquired in 4 healthy subjects for a total of 100 min after i.v. injection of 400 ± 8 MBq of [ C]elacridar using a Siemens Biograph scanner. Volumes of interest were placed in the brain, liver, pancreas, gallbladder, kidneys, lung, muscle, heart, spleen, bone marrow and bile by using ROVER (v. 2.0.31, ABX, Germany) software. Residence times were derived by spreadsheet calculation and adapted to the standard human model. Organ doses and effective dose were calculated utilizing the OLINDA (v. 1.1, Vanderbilt University) dosimetry program. Organs with highest radiation burden included pancreas, spleen, liver and gallbladder wall. Furthermore, lungs, heart wall and kidneys received above average organ doses. As excretory organ the gallbladder was identified. Monoexponential fitting of activity overlying the gallbladder suggested that >95% of activity was excreted via the bile. The calculated effective dose was 7.0×10 mSv/MBq yielding 2.8 mSv for an injected amount of 400 MBq of [ C]elacridar. The estimated radiation burden of [ C]elacridar is in the range of other C-labeled PET tracers and would allow multiple PET examinations of the same subject per year.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=5; title_english_share=0.2632; title_reads=english; abstract_words=270; abstract_english_function_words=81; abstract_english_share=0.3000; abstract_reads=english; language_check=metadata_listed