Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
[11C]Elacridar as a novel P-glycoprotein PET tracer, assessment of whole-body distribution and radiation dosimetry in humans
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
The ATP-binding cassette transporter P-glycoprotein (P-gp) is expressed at the blood-brain barrier (BBB) where it protects the brain from toxic substances and xenobiotics by active efflux transport. The C-labelled third-generation P-gp inhibitor [ C]elacridar was developed as a positron emission tomography (PET) tracer for the in vivo quantification of P-gp expression levels in different organs. The aim of this study was to provide human dosimetry estimates for [ C]elacridar based on whole-body PET. Whole-body low dose computed tomography (CT) and dynamic and static whole-body PET scans were acquired in 4 healthy subjects for a total of 100 min after i.v. injection of 400 ± 8 MBq of [ C]elacridar using a Siemens Biograph scanner. Volumes of interest were placed in the brain, liver, pancreas, gallbladder, kidneys, lung, muscle, heart, spleen, bone marrow and bile by using ROVER (v. 2.0.31, ABX, Germany) software. Residence times were derived by spreadsheet calculation and adapted to the standard human model. Organ doses and effective dose were calculated utilizing the OLINDA (v. 1.1, Vanderbilt University) dosimetry program. Organs with highest radiation burden included pancreas, spleen, liver and gallbladder wall. Furthermore, lungs, heart wall and kidneys received above average organ doses. As excretory organ the gallbladder was identified. Monoexponential fitting of activity overlying the gallbladder suggested that >95% of activity was excreted via the bile. The calculated effective dose was 7.0×10 mSv/MBq yielding 2.8 mSv for an injected amount of 400 MBq of [ C]elacridar. The estimated radiation burden of [ C]elacridar is in the range of other C-labeled PET tracers and would allow multiple PET examinations of the same subject per year.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=19; title_english_function_words=5; title_english_share=0.2632; title_reads=english; abstract_words=270; abstract_english_function_words=81; abstract_english_share=0.3000; abstract_reads=english; language_check=metadata_listed