Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Low-dose computed tomography of urolithiasis in obese patients: a feasibility study to evaluate image reconstruction algorithms
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Purpose: Retrospective evaluation and comparison of image quality generated by low-dose computed tomography (LDCT) from obese patients with urolithiasis using alternative reconstruction algorithms. Materials and methods: Twenty-five obese patients (body mass index [BMI]>25 kg/m 2, ) underwent LDCT scans for suspected urolithiasis. The scans were recompiled using filtered-back projection (FBP), statistical iterative reconstruction (iDose) and iterative model-based reconstruction (IMR). Dose-length product (DLP) and patient details were obtained from the CT dose report and clinical charts, respectively. Objective image noise was assessed by measuring the SD of Hounsfield units (HUs) in defined locations. Additionally, subjective image evaluation was independently performed by two radiologists using a 3-point Likert scale. The inter-reviewer agreement of image quality was calculated. Results: Ureteral concretions were observed in all CT scans, two of which revealed bilateral stones. The assessed patients’ mean BMI was 29.29±3.74 kg/m, 2 and the DLP of the CT scans was 100.04±10.00 mGy*cm. All scans were rated diagnostic with the iDose and iterative model-based reconstructions, whereas 41% of the scans performed with FBP reconstruction were nondiagnostic. With respect to image quality, IMR was superior to iDose and FBP, both in the objective ( P <0.001) and overall subjective ( P ≤0.008) evaluation of the respective data sets. The inter-reviewer agreement for overall image quality was “almost perfect” for IMR, “substantial” for iDose and “moderate” for FBP (κ values of 1.0, 0.6 and 0.46, respectively). Conclusion: Using iterative image reconstruction algorithms, LDCT of urolithiasis is feasible in overweight patients with a BMI between 25 and 35 kg/m 2, . Due to higher image quality, IMR is the preferred algorithm for scan reconstruction as it may help to avoid repeated examinations due to initial nondiagnostic scans. Keywords: low-dose computed tomography, model-based iterative reconstruction, statistical iterative, urolithiasis, obesity
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=17; title_english_function_words=4; title_english_share=0.2353; title_reads=english; abstract_words=288; abstract_english_function_words=84; abstract_english_share=0.2917; abstract_reads=english; language_check=metadata_listed