Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Simulation of scanner- and patient-specific low-dose CT imaging from existing CT images

Robiël E. Naziroglu; Vincent F. van Ravesteijn; Lucas J. van Vliet; Geert J. Streekstra; Frans M. Vos (2017). Physica Medica

DOI 10.1016/j.ejmp.2017.02.009

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: Simulating low-dose Computed Tomography (CT) facilitates in-silico studies into the required dose for a diagnostic task. Conventionally, low-dose CT images are created by adding noise to the projection data. However, in practice the raw data is often simply not available. This paper presents a new method for simulating patient-specific, low-dose CT images without the need of the original projection data. METHODS: The low-dose CT simulation method included the following: (1) computation of a virtual sinogram from a high dose CT image through a radon transform; (2) simulation of a 'reduced'-dose sinogram with appropriate amounts of noise; (3) subtraction of the high-dose virtual sinogram from the reduced-dose sinogram; (4) reconstruction of a noise volume via filtered back-projection; (5) addition of the noise image to the original high-dose image. The required scanner-specific parameters, such as the apodization window, bowtie filter, the X-ray tube output parameter (reflecting the photon flux) and the detector read-out noise, were retrieved from calibration images of a water cylinder. The low-dose simulation method was evaluated by comparing the noise characteristics in simulated images with experimentally acquired data. RESULTS: The models used to recover the scanner-specific parameters fitted accurately to the calibration data, and the values of the parameters were comparable to values reported in literature. Finally, the simulated low-dose images accurately reproduced the noise characteristics in experimentally acquired low-dose-volumes. CONCLUSION: The developed methods truthfully simulate low-dose CT imaging for a specific scanner and reconstruction using filtered backprojection. The scanner-specific parameters can be estimated from calibration data.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=265; abstract_english_function_words=84; abstract_english_share=0.3170; abstract_reads=english; language_check=metadata_listed