Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Deep Learning Models for Low-Dose CT Denoising: A Forward Survey (2022–2025)

Wang Zhang; Chin Kim On; Rayner Alfred; Soo See Chai; Chew Chiou Sheng (2025). International Conference on Advances in Machine Intelligence and Cybersecurity Technologies (AMICT)

DOI 10.1109/amict65811.2025.11402821

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose Computed Tomography (LDCT) can reduce radiation exposure, but it also increases image noise, significantly elevating diagnostic risks. While traditional deep learning-based denoising methods effectively suppress noise, their over-reliance on metrics such as Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) often results in overly smooth images, leading to the loss of critical pathological features such as microcalcifications and ground-glass nodules. Therefore, there is an urgent need to establish a comprehensive evaluation framework that balances perceptual quality with diagnostic efficacy, and to develop adaptive denoising strategies driven by diagnostic tasks. This paper summarizes research findings from recent years (2022–2025) focused on perceptual quality. Currently, methods based on convolutional neural networks, generative adversarial networks, Transformer architectures, and their variants (such as Mamba), as well as diffusion models, have achieved notable breakthroughs in detail preservation. These advancements are accompanied by continuous innovation in optimizer design, loss functions, and evaluation systems. This work systematically reviews the latest progress in the field, highlights the strengths and limitations of existing methods in optimizing perceptual quality, and provides a reference for future research on diagnosis-oriented LDCT denoising.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=11; title_english_function_words=2; title_english_share=0.1818; title_reads=english; abstract_words=188; abstract_english_function_words=59; abstract_english_share=0.3138; abstract_reads=english; language_check=metadata_listed