Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Lung cancer screening with MRI: characterization of nodules with different non-enhanced MRI sequences

Michael Meier-Schroers; Rami Homsi; Hans Heinz Schild; Daniel Thomas (2018). Acta Radiologica

DOI 10.1177/0284185118778870

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: There is increased interest in pulmonary magnetic resonance imaging (MRI) as a radiation-free alternative to computed tomography (CT) for lung cancer screening. PURPOSE: To analyze MRI characteristics of pulmonary nodules with different non-enhanced sequences. MATERIAL AND METHODS: Eighty-two participants of a lung cancer screening were included. MRI datasets of 32 individuals with 46 different nodules ≥ 6 mm were prospectively evaluated together with 50 controls by two readers. Acquired sequences were T2- short tau inversion recovery (STIR), T2, balanced steady-state free precession (bSSFP), 3D-T1, and diffusion-weighted imaging (DWI). Each sequence was randomly and separately viewed blinded to low-dose CT (LDCT). Size, shape, and contrast of nodules were evaluated on each sequence and then correlated with LDCT and histopathology. RESULTS: All eight carcinomas were detected by T2-STIR, T2, and bSSFP, and 7/8 by 3D-T1. Contrast was significantly higher for malignant nodules on all sequences. The highest contrast ratio between malignant and benign nodules was provided by T2-STIR. Of eight carcinomas, seven showed restricted diffusion. Size measurement correlated significantly between MRI and LDCT. Sensitivity/specificity for nodules ≥ 6 mm was 85-89%/92-94% for T2-STIR, 80-87%/93-96% for T2, 65-70%/96-98% for bSSFP, and 63-67%/96-100% for 3D-T1. Seven of eight subsolid nodules were visible on T2-sequences with significantly lower lesion contrast compared to solid nodules. Two of eight subsolid nodules were detected by bSFFP, none by 3D-T1. All three calcified nodules were detected by 3D-T1, one by bSSFP, and none by T2-sequences. CONCLUSION: Malignant as well as calcified and subsolid nodules seem to have distinctive characteristics on different MRI sequences. T2-imaging was most suitable for the detection of nodules ≥ 6 mm.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=271; abstract_english_function_words=85; abstract_english_share=0.3137; abstract_reads=english; language_check=metadata_listed