Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

SPECTCT cerebral perfusion scintigraphy; is the low-dose CT component of diagnostic value?

Tom Sulkin; C. Cousens (2007). Clinical Radiology

DOI 10.1016/j.crad.2007.08.004

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

AIM: To assess the potential diagnostic value of the low-dose computed tomography (CT) component of dual-examination single photon emission CT and CT (SPECTCT) cerebral perfusion studies. METHOD AND MATERIALS: Two hundred and forty consecutive 99 mTc hexamethylpropylene amine oxime (HMPAO) SPECTCT studies were considered for inclusion. The images were acquired on a hybrid dual-head gamma camera/low-dose CT system. The CT component had a fixed tube current of 2.5 mA. The CT section thickness was 5mm and total acquisition time approximately 7.5 min. Studies in which no CT images were acquired, or those excessively degraded by movement artefact were excluded. The CT images of each of the remaining studies were retrospectively reviewed and categorized as normal or abnormal. Details of the abnormalities were recorded. RESULTS: Fifteen of the 240 studies were excluded as no CT images were obtained. A further 14 were excluded as they were considered excessively degraded by movement artefact. A single abnormality was demonstrated on 48 (23%), and two abnormalities on four (2%) of the remaining 211 studies. The most common abnormal findings were low attenuation in the deep cortical white matter (n=22), infarcts (n=12), cerebral atrophy (n=7), dilated ventricles (n=5), basal ganglia calcification (n=4), and post-surgical change (n=3). Other findings included a chronic subdural haematoma, a meningioma, and a posterior fossa cyst. Previous cerebral imaging was available for comparison in 31% of cases. There was 85% concordance between previous imaging and the low-dose CT images. CONCLUSION: Twenty-five percent of the low-dose CT images in this study demonstrated abnormalities. Therefore the CT component of cerebral perfusion SPECTCT investigations should be routinely reported in their own right.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=266; abstract_english_function_words=89; abstract_english_share=0.3346; abstract_reads=english; language_check=metadata_listed