Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

3D Multi-Branch Encoder-Decoder Networks with Attentional Feature Fusion for Pulmonary Nodule Detection in CT Scans

Chenjiao Zhang; Lulu Wang; Xing Li Wu; Zhongshi He (2021). International Joint Conference on Neural Networks (IJCNN)

DOI 10.1109/ijcnn52387.2021.9533851

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Pulmonary nodule detection in low-dose computed tomography (CT) images is essential for early screening and treatment of lung cancer. Previous related researches based on deep convolutional neural networks generally rely on 2D or 2.5D components and only focus on the output feature information under a single receptive field. Considering the 3D nature of lung CT images and the performance limitation of state-of-the-art nodule detection methods, we develop a novel 3D multi-branch region proposal network with an encoder-decoder structure. Specifically, each parallel branch is designed with 3D residual blocks and U-Net-like structure to effectively extract multi-scale fusion features based on 3D spatial information of CT scans, and the strategies of varying receptive fields and sharing weight parameters are used to improve the sensitivity of the detection network to nodules with scale variation and maintain the original parameters. Besides, we propose a multi-scale attentional feature fusion module to better fuse high-resolution and semantically strong features and adaptively learn the inter-dependency information of different feature maps. Finally, we compare a dynamically scaled cross entropy loss and online hard example mining (OHEM) to combat the imbalance of positive and negative samples during training, which is aimed at assisting with network optimization. Our extensive experiments on publicly available CT scans obtained from LUNA16 and TianChi1competition dataset demonstrate that our method outperform state-of-the-art pulmonary nodule detection models.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=3; title_english_share=0.1765; title_reads=english; abstract_words=237; abstract_english_function_words=69; abstract_english_share=0.2911; abstract_reads=english; language_check=metadata_listed