Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Ultra-low-dose computed tomography system with a flat panel detector: assessment of radiation dose reduction and spatial and low contrast resolution
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
PURPOSE: The aim of this study was to introduce a prototype cone-beam computed tomography system equipped with a flat panel detector (FPD-CT system) and measure its radiation dose and spatial and lowcontrast resolution. MATERIALS AND METHODS: A patient was rotated in a sitting position, and cone beam data were acquired with the flat panel detector from a fixed X-ray tube. Absorbed dose, spatial and low-contrast resolution, and variation in the CT attenuation value were assessed quantitatively in the acrylic phantom. The visibility of normal blood vessels in clinical images of seven patients was analyzed qualitatively by five board-certified radiologists. These quantitative and qualitative data were compared between the FPD-CT system and multidetector row CT (MDCT). RESULTS: Minimal low-contrast sensitivity and a moderate spatial resolution were demonstrated in images of central lung fields acquired by FPD-CT. The absorbed dose in the FPD-CT system decreased to approximately 2.5% of the dose in the MDCT system. CONCLUSION: Considering crossover structures in normal blood vessels and bronchi in the central areas of lung fields, this result implies that fairly acceptable spatial resolution can be realized with FPD-CT for detection and frequent follow-up of pulmonary abnormalities in the central lung fields.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=22; title_english_function_words=5; title_english_share=0.2273; title_reads=english; abstract_words=206; abstract_english_function_words=71; abstract_english_share=0.3447; abstract_reads=english; language_check=metadata_listed