Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Initial experience of SPECT/CT in the diagnosis of occult scaphoid fracture

Andele D de Zwart; Frank J. P. Beeres; Daphne D. D. Rietbergen; Pieta Krijnen; Inger Birgitta Schipper (2015). Acta Radiologica Open

DOI 10.1177/2058460115602729

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: *Equal contributors.Planar bone scintigraphy (PBS) is often advocated for diagnosing occult scaphoid fractures. PBS is a sensitive diagnostic modality, but lacks specificity, which may result in over-diagnosis. PURPOSE: To examine, in a pilot study, the potential additional value of single photon emission computed tomography (SPECT) combined with low dose computed tomography (CT) for the diagnosis of an occult scaphoid fracture. MATERIAL AND METHODS: Ten patients that underwent combined PBS and SPECT/CT for a clinically suspected scaphoid fracture, where radiographs could not detect a fracture, were included in this pilot study. The PBS and SPECT/CT results were independently and separately evaluated by a nuclear physician for scaphoid fractures and other injuries. RESULTS: PBS was positive for a scaphoid fracture in four patients and diagnosed three other fractures. SPECT/CT showed five scaphoid fractures and one other fracture. SPECT/CT - PBS had discrepant results in three patients. In two patients PBS diagnosed a trapezoid fracture where SPECT/CT showed a scaphoid fracture. The other patient was diagnosed with a scaphoid fracture on PBS, whereas SPECT/CT showed bone bruise of other carpal bones. CONCLUSION: SPECT/CT has the potential to be more accurate than PBS as it uses anatomical information of the CT to discriminate between the scaphoid, other carpal bones, and bone bruises. Larger studies with an independent reference standard are needed for confirmation of these preliminary data.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=4; title_english_share=0.3333; title_reads=english; abstract_words=232; abstract_english_function_words=84; abstract_english_share=0.3621; abstract_reads=english; language_check=metadata_listed