Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Lung Cancer Screening CT

Stuart L. Cohen; JASON J. WANG; Nicholas Chan; William O’Connell; Rakesh D. Shah; Pina C. Sanelli; Suhail Raoof (2019). CHEST Journal

DOI 10.1016/j.chest.2019.07.024

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Effective dose (ED) is used to understand radiation-related cancer risk of CT scans. Currently, ED for low-dose CT (LDCT) lung cancer screening (LCS) is estimated by multiplying the CT scan-reported dose-length product (DLP) by a DLP-to-ED conversion factor (k-factor) for general chest CT imaging, which does not account for sex. The purpose of this study was to calculate sex-specific k-factors for LDCT LCS. METHODS: This retrospective study evaluated consecutive LCS patients across a large health system from 2016 to 2017. Patient and CT scan-related data were obtained from the radiology information system, the picture archiving and communication system, and a radiation dose index-monitoring system. Each patient's ED was determined by patient-specific Monte-Carlo simulation using Cristy phantoms and divided by study DLP to determine the k-factor. The k-factors were compared vs the standard of 0.014 mSv·mGy⁻1·cm⁻1 for a chest CT scan by using a one-sample Student t test. Bivariate and multivariable analyses were performed for k-factors based on patient and CT scan factors. RESULTS: A total of 1,890 patients were included in the study. The mean k-factor for all patients was 0.0179 mSv·mGy⁻1·cm⁻1, which was 22% greater than the standard value of 0.014 mSv·mGy⁻1·cm⁻1 for a chest CT scan previously applied to LDCT imaging (P < .001). The mean k-factor in women (0.0213 mSv·mGy⁻1·cm⁻1) was 43% greater than in men (0.0149 mSv·mGy⁻1·cm⁻1) in the multivariable model (P < .001). CONCLUSIONS: The overall k-factor for LCS is higher than the previously used value for chest CT imaging; when stratified according to sex, it was 43% greater in women than in men. Sex- and LCS-specific k-factors should be used to estimate effective radiation dose in LCS programs.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=4; title_english_function_words=0; title_english_share=0.0000; title_reads=not_english; abstract_words=293; abstract_english_function_words=96; abstract_english_share=0.3276; abstract_reads=english; language_check=metadata_listed