Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Reliability of High-Pitch Ultra-Low-Dose Paranasal Sinus Computed Tomography for Evaluating Paranasal Sinus Anatomy and Sinus Disease

Elif Ayanoglu Aksoy; Sila Ulus Özden; Ercan Karaarslan; Ömer Faruk Ünal; Hasan Tanyeri (2014). Journal of Craniofacial Surgery

DOI 10.1097/scs.0000000000000966

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: The aim of this study was to evaluate the reliability of high-pitch ultra-low-dose computed tomography (CT) for detecting important paranasal sinus anatomic landmarks and pathologies. MATERIALS AND METHODS: Sixty patients (22 females, 38 males) aged 15 to 67 years (mean age, 33.68 y; SD, 9.83 y) underwent high-pitch ultra-low-dose CT of the paranasal sinuses between February and June 2012. To determine the lowest possible dose for evaluation of the paranasal sinuses, the patients were divided into three groups randomly and prospectively. A different low-dose CT protocol was applied to each group. The image quality was assessed subjectively by a radiologist and an otorhinolaryngology head and neck surgeon independently using a 4-point grading scale (0 = structures could not be identified, 1 = indistinctly defined structures, 1.5 = relatively well-defined structures, 2 = very well-defined structures). Anatomic landmarks and mucosal structures were evaluated. Mean scores were evaluated to assess statistical significance. RESULTS: According to the anatomic landmark scoring, excluding the ethmoid foramen for ethmoid artery identification, all of the structures in all 3 groups were very well-defined structures. The ethmoid foramen for ethmoid artery identification was scored as either could not be identified or an indistinctly defined structure in all groups. On evaluating the mucosa of the paranasal sinuses, normal and pathologic mucosal structures were scored as very well defined in all of the patients. The interobserver agreement was excellent. CONCLUSION: High-pitch ultra-low-dose CT is a safe, reliable paranasal sinus screening tool.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=3; title_english_share=0.1579; title_reads=english; abstract_words=239; abstract_english_function_words=83; abstract_english_share=0.3473; abstract_reads=english; language_check=metadata_listed