Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Methylene Blue–Guided Localization to Improve Accuracy and Safety in Pulmonary Nodule Resection
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Objective: The increasing detection of small and non-palpable pulmonary nodules through low-dose computed tomography (CT) screening has highlighted the need for reliable intraoperative localization, particularly during video-assisted thoracoscopic surgery (VATS).CT-guided methylene blue marking is a simple, rapid, and widely accessible technique that facilitates minimally invasive resection.This study aimed to evaluate the technical success, safety profile, and determinants of outcomes in CT-guided methylene blue localization of pulmonary nodules.Methods: This retrospective study included 49 consecutive patients who underwent preoperative CT-guided methylene blue localization followed by thoracic resection, predominantly via VATS, between 2020 and 2025.Demographic characteristics, nodule morphology, procedural parameters, surgical details, and postoperative outcomes were analyzed.Categorical variables were compared using Chi-square or Fisher-based tests, and continuous variables using the Mann-Whitney U test.Results: Localization was successful in 47 of 49 patients, yielding a technical success rate of 95.9%.Two unsuccessful localizations (4.1%) occurred, both in lower-lobe lesions and both associated with complications.Localization-related adverse events developed in nine patients (18.4%), most commonly pneumothorax (12.2%) and parenchymal hemorrhage (6.1%).The median patient age was 63 years, and the median nodule diameter was 9 mm.Malignancy was identified in 69.4% of nodules.No significant associations were found between localization success and nodule type, FDG uptake, lobar distribution, resection type, or procedural parameters.Tumor size showed a non-significant trend toward association with malignancy.Conclusion: CT-guided methylene blue localization is a safe, highly effective, and practical technique for facilitating thoracoscopic resection of small pulmonary nodules.Technical success is consistently high and appears largely independent of radiological, anatomical, or procedural factors.These findings support the use of methylene blue marking as a reliable adjunct to minimally invasive thoracic surgery.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=277; abstract_english_function_words=73; abstract_english_share=0.2635; abstract_reads=english; language_check=metadata_listed