Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

AI-Enhanced Hybrid Optimization and Deep Network Architecture for Noise Reduction in Low-Dose Medical Imaging

M Kristappa; Krishnanaik Vankdoth (2026). International Journal of Computer Information Systems and Industrial Management Applications

DOI 10.70917/ijcisim-2026-4478

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (LDCT) is a significant non-invasive imaging modality for disease diagnosis in early stages and clinical oncology. However, the reduction of radiation dose unavoidably introduces severe quantum noise, photon starvation and Poisson-Gaussian noise, which degrade contrast-to-noise ratio (CNR) and obscure subtle anatomical details. Recent advances in Artificial Intelligence (AI) have shown great promise in medical image restoration. However, pure deep learning methods often suffer from over-smoothing of fine structures and poor interpretability, while traditional non-convex variational models can preserve global edges, but are sensitive to the choice of parameters and produce staircasing artifacts. We propose an AI-empowered hybrid restoration framework that combines non-convex Total Variation (TV) optimization and a deep convolutional residual network within the Plug-and-Play (PnP) Alternating Direction Method of Multipliers (ADMM) framework to enjoy the complementary merits of the two paradigms. The AI based deep residual network can learn complex noise features and image priors efficiently. The optimization part keeps the structural fidelity and ensures the stable reconstruction. The proposed framework is tested on clinical lung CT slices from LIDC-IDRI benchmark dataset, and the experimental results show that the proposed framework achieves 33.97dB of Peak Signal-to-Noise Ratio (PSNR) and 0.918 of Structural Similarity Index Measure (SSIM) at noise level of σ=25. The experimental results show that the proposed AI-enabled hybrid model can better preserve structure edges, recover fine anatomical details and suppress noise compared with the traditional optimization methods and deep learning alone, which shows the effectiveness for low-dose medical image denoising.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=3; title_english_share=0.1875; title_reads=english; abstract_words=261; abstract_english_function_words=72; abstract_english_share=0.2759; abstract_reads=english; language_check=metadata_listed